Multiplex Assay Kit for S-Adenosyl Methionine (SAM) ,etc. by FLIA (Flow Luminescence Immunoassay)
SAMe; SAM-e; S-Adenosylmethionine; S-(5'-Adenosyl)-L-Methionine Chloride
(Note: Up to 8-plex in one testing reaction)
- Product No.LMG414Ge
- Organism SpeciesPan-species (General) Same name, Different species.
- Sample Typeserum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodCompetitive Inhibition
- Assay Length1.5h
- Detection Range0.98-1000ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.327 ng/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 509
US$ 529
US$ 558
US$ 597
US$ 636
US$ 695
US$ 783
Result
For more details, please contact local distributors! US$ 979 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of S-Adenosyl Methionine (SAM) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between S-Adenosyl Methionine (SAM) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of S-Adenosyl Methionine (SAM) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of S-Adenosyl Methionine (SAM) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 78-103 | 88 |
EDTA plasma(n=5) | 88-95 | 91 |
heparin plasma(n=5) | 92-101 | 96 |
sodium citrate plasma(n=5) | 81-98 | 88 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level S-Adenosyl Methionine (SAM) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level S-Adenosyl Methionine (SAM) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of S-Adenosyl Methionine (SAM) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 94-102% | 96-104% | 96-105% | 79-101% |
EDTA plasma(n=5) | 86-97% | 97-105% | 79-93% | 78-95% |
heparin plasma(n=5) | 90-103% | 86-94% | 92-102% | 85-96% |
sodium citrate plasma(n=5) | 87-98% | 92-99% | 84-94% | 97-104% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:SAM) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Cell Death and Disease | Hyperhomocysteinemia causes ER stress and impaired autophagy that is reversed by Vitamin B supplementation pubmed:27929536 |
PLoS One | Attenuated expression of MTR in both prenatally androgenized mice and women with the hyperandrogenic phenotype of PCOS pubmed:29232372vvvv |
Microbial Cell Factories | Metabolic engineering of Acremonium chrysogenum for improving cephalosporin C production independent of methionine stimulation Pubmed:29879990 |
Cell Metabolism | Serine metabolism antagonizes antiviral innate immunity by preventing ATP6V0d2-mediated YAP lysosomal degradation 33798471 |
Catalog No. | Related products for research use of Pan-species (General) Organism species | Applications (RESEARCH USE ONLY!) |
CPG414Ge11 | BSA Conjugated S-Adenosyl Methionine (SAM) | Immunogen; SDS-PAGE; WB. |
CPG414Ge21 | OVA Conjugated S-Adenosyl Methionine (SAM) | Immunogen; SDS-PAGE; WB. |
PAG414Ge01 | Polyclonal Antibody to S-Adenosyl Methionine (SAM) | ELISA, CLIA. / IHC-Fr, ICC, IP (predicted). |
PAG414Ge02 | Polyclonal Antibody to S-Adenosyl Methionine (SAM) | ELISA, CLIA. / IHC-Fr, ICC, IP (predicted). |
MEG414Ge | Mini Samples ELISA Kit for S-Adenosyl Methionine (SAM) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CEG414Ge | ELISA Kit for S-Adenosyl Methionine (SAM) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMG414Ge | Multiplex Assay Kit for S-Adenosyl Methionine (SAM) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
KSG414Ge11 | ELISA Kit DIY Materials for S-Adenosyl Methionine (SAM) | Main materials for "Do It (ELISA Kit) Yourself". |