Multiplex Assay Kit for Tyrosine 3/Tryptophan 5 Monooxygenase Activation Protein Zeta (YWHAz) ,etc. by FLIA (Flow Luminescence Immunoassay)

KCIP-1; 14-3-3-zeta; 14-3-3 protein zeta/delta; Protein kinase C inhibitor protein 1

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity for detection of Tyrosine 3/Tryptophan 5 Monooxygenase Activation Protein Zeta (YWHAz) ,etc. by FLIA (Flow Luminescence Immunoassay).
100% cross-reactivity of Tyrosine 3/Tryptophan 5 Monooxygenase Activation Protein Zeta (YWHAz) ,etc. by FLIA (Flow Luminescence Immunoassay) was observed among Human, Mouse, Rat.

Recovery

Matrices listed below were spiked with certain level of recombinant Tyrosine 3/Tryptophan 5 Monooxygenase Activation Protein Zeta (YWHAz) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Tyrosine 3/Tryptophan 5 Monooxygenase Activation Protein Zeta (YWHAz) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 97-105 101
EDTA plasma(n=5) 79-101 96
heparin plasma(n=5) 90-102 97

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Tyrosine 3/Tryptophan 5 Monooxygenase Activation Protein Zeta (YWHAz) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Tyrosine 3/Tryptophan 5 Monooxygenase Activation Protein Zeta (YWHAz) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Tyrosine 3/Tryptophan 5 Monooxygenase Activation Protein Zeta (YWHAz) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 93-101% 90-97% 96-105% 88-95%
EDTA plasma(n=5) 98-105% 80-89% 86-104% 98-105%
heparin plasma(n=5) 93-101% 79-98% 93-105% 96-104%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:YWHAz) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Toxicology Research Differential expression of serum proteins in rats subchronically exposed to arsenic identified by iTRAQ-based proteomic technology—14-3-3 ζ protein to serve as a potential biomarker content:c5tx00393h
Toxicology Research Differential expression of serum proteins in rats subchronically exposed to arsenic identified by iTRAQ-based proteomic technology—14-3-3 ζ protein to serve … c5tx00393h
Bulletin of Experimental Biology and Medicine Influence of Magnetite Nanoparticles and Quantum Dots on the Expression of Reference Genes in Peripheral Blood Cells Pubmed: 30488202
Catalog No. Related products for research use of Homo sapiens (Human), Mus musculus (Mouse), Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
SEJ809Mi ELISA Kit for Tyrosine 3/Tryptophan 5 Monooxygenase Activation Protein Zeta (YWHAz) Enzyme-linked immunosorbent assay for Antigen Detection.
LMJ809Mi Multiplex Assay Kit for Tyrosine 3/Tryptophan 5 Monooxygenase Activation Protein Zeta (YWHAz) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.