Multiplex Assay Kit for C1q And Tumor Necrosis Factor Related Protein 3 (C1QTNF3) ,etc. by FLIA (Flow Luminescence Immunoassay)

CORS26; CTRP3; Corcs; Cors; Cartonectin; Collagenous repeat-containing sequence 26 kDa protein

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of C1q And Tumor Necrosis Factor Related Protein 3 (C1QTNF3) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between C1q And Tumor Necrosis Factor Related Protein 3 (C1QTNF3) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant C1q And Tumor Necrosis Factor Related Protein 3 (C1QTNF3) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of C1q And Tumor Necrosis Factor Related Protein 3 (C1QTNF3) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 89-105 101
EDTA plasma(n=5) 89-103 98
heparin plasma(n=5) 94-103 98
sodium citrate plasma(n=5) 99-105 102

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level C1q And Tumor Necrosis Factor Related Protein 3 (C1QTNF3) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level C1q And Tumor Necrosis Factor Related Protein 3 (C1QTNF3) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of C1q And Tumor Necrosis Factor Related Protein 3 (C1QTNF3) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 80-101% 78-101% 94-101% 86-93%
EDTA plasma(n=5) 95-102% 98-105% 93-102% 79-104%
heparin plasma(n=5) 94-102% 95-102% 78-103% 90-99%
sodium citrate plasma(n=5) 87-98% 94-104% 78-103% 94-103%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:C1QTNF3) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
PLoS One. Low Serum Cartonectin/CTRP3 Concentrations in Newly Diagnosed Type 2 Diabetes Mellitus: In Vivo Regulation of Cartonectin by Glucose Pubmed:25409499
BMC Cardiovascular Disorders Serum levels of C1q/TNF-related protein-1 (CTRP-1) are closely associated with coronary artery disease Pubmed:27169633
Journal of Diabetes Research Plasma C1q/TNF-Related Protein-3 (CTRP-3) and High-Mobility Group Box-1 (HMGB-1) Concentrations in Subjects with Prediabetes and Type 2 Diabetes pubmed:27738641
Journal of Clinical Medicine Circulating C1q/TNF-Related Protein 3, Omentin-1 and NGAL in Obese Patients with Type 2 Diabetes During Insulin Therapy Pubmed: 31195747
Cell Death & Disease C1q-TNF-related protein-3 attenuates pressure overload-induced cardiac hypertrophy by suppressing the p38/CREB pathway and p38-induced ER stress Pubmed: 31285424
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPK169Hu01 Recombinant C1q And Tumor Necrosis Factor Related Protein 3 (C1QTNF3) Positive Control; Immunogen; SDS-PAGE; WB.
PAK169Hu01 Polyclonal Antibody to C1q And Tumor Necrosis Factor Related Protein 3 (C1QTNF3) WB; IHC; ICC; IP.
MAK169Hu21 Monoclonal Antibody to C1q And Tumor Necrosis Factor Related Protein 3 (C1QTNF3) WB; IHC; ICC; IP.
SEK169Hu ELISA Kit for C1q And Tumor Necrosis Factor Related Protein 3 (C1QTNF3) Enzyme-linked immunosorbent assay for Antigen Detection.
LMK169Hu Multiplex Assay Kit for C1q And Tumor Necrosis Factor Related Protein 3 (C1QTNF3) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.