Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Pentraxin 3, Long (PTX3) ,etc. by FLIA (Flow Luminescence Immunoassay)
TNFAIP5; TSG-14; Pentaxin-Related Gene,Rapidly Induced By IL-1 Beta; Tumor Necrosis Factor Alpha-Induced Protein 5; Tumor necrosis factor-inducible gene 14 protein
(Note: Up to 8-plex in one testing reaction)
- Product No.LMK411Mu
- Organism SpeciesMus musculus (Mouse) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates, cell lysates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range1.95-2000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.65 pg/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 449
US$ 467
US$ 492
US$ 527
US$ 562
US$ 613
US$ 691
Result
For more details, please contact local distributors! US$ 864 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Pentraxin 3, Long (PTX3) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Pentraxin 3, Long (PTX3) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Pentraxin 3, Long (PTX3) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Pentraxin 3, Long (PTX3) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 92-99 | 95 |
EDTA plasma(n=5) | 80-89 | 86 |
heparin plasma(n=5) | 97-104 | 101 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Pentraxin 3, Long (PTX3) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Pentraxin 3, Long (PTX3) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Pentraxin 3, Long (PTX3) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 87-95% | 80-91% | 91-98% | 95-103% |
EDTA plasma(n=5) | 82-95% | 84-95% | 81-104% | 93-101% |
heparin plasma(n=5) | 98-105% | 79-95% | 90-99% | 95-103% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:PTX3) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Mediators of Inflammation | Biochemical Analysis of Pentraxin 3 and Fibrinogen Levels in Experimental Periodontitis Model PubMed: 22966213 |
Ibnosina Journal of Medicine and Biomedical Sciences | Effect of Vagus Nerve Stimulation on Focal Transient Cerebral Ischemia and Reperfusion in Adult Male White New Zealand Rabbits Sfu: Source |
Hemodialysis International | Hemodialysis-induced changes in the blood composition affect function of the endothelium Onlinelibrary: hdi.12148 |
Hemodial Int. | Hemodialysis‐induced changes in the blood composition affect function of the endothelium Pubmed:24612443 |
Journal of Obstetrics and Gynaecology Research | The effects of sunitinib on endometriosis Pubmed:25093747 |
Gynecol Endocrinol. | Exenatide improves ovarian and endometrial injury and preserves ovarian reserve in streptozocin induced diabetic rats Pubmed:25366063 |
Taiwanese Journal of Obstetrics and Gynecology | Ovarian failure in diabetic rat model: Nuclear factor-kappaB, oxidative stress, and pentraxin-3 Pubmed:25510691 |
Journal of Obstetrics and Gynaecology Research | Octreotide protects ovary against ischemia–reperfusion injury in rats: Evaluation of histological and biochemical parameters PubMed: 26223286 |
J Obstet Gynaecol | The long pentraxin-3 is a useful marker for diagnosis of ovarian torsion: An experimental rat model PubMed: 26470829 |
Neurology Research International | Accumulation of α-Synuclein in Cerebellar Purkinje Cells of Diabetic Rats and Its Potential Relationship with Inflammation and Oxidative Stress Markers 5952149 |
Journal of Diabetes Research | Study on Association of Pentraxin 3 and Diabetic Nephropathy in a Rat Model Pubmed:29725602 |
World Journal of Cardiovascular Diseases | The Relationship between Serum Pentraxin-3 Levels and Severity of Coronary Heart Disease paperID:86206 |
Advances in Medical Sciences | Serum levels and gene expression of pentraxin 3 are elevated in COPD Pubmed: 30572222 |
BioMed Research International | Pentraxin 3 Detects Clinically Significant Fibrosis in Patients with Chronic Viral Hepatitis C |
Evidence-Based Complementary and Alternative Medicine | Jie Du Tong Ye San Prevents N-Nitrosomethylbenzylamine-Induced Esophageal Carcinogenesis via Inhibition of Inflammation and Proliferation |
Journal of Interferon and Cytokine Research | Study on Serum Pentraxin-3 Levels in Vasculitis with Hypertension Pubmed: 31264920 |
Scientific Reports | The role of CRP and Pentraxin 3 in the prediction of systemic inflammatory response syndrome and death in acute pancreatitis Pubmed: 31798002 |
J Obstet Gynaecol | Losartan ameliorates ovarian ischaemia/reperfusion injury in rats: an experimental study Pubmed: 31955629 |
J Pediatr Adolesc Gynecol | Effects of Methylene Blue on Ovarian TorsionLDetorsion Injury in a Rat Model Pubmed: 32593749 |
Acta Cirurgica Brasileira | Therapeutic effects of vitamin D on acetic acid-induced colitis in rats Pubmed: 32555936 |
Acta Cardiol Sin | Pentraxin 3 as a marker for cardiovascular disease risk in overweight and obese children 33716459 |
International Journal of Endocrinology | Effect of Ileal Transposition (IT) on Angiopoietin-Like Protein-8 (ANGPTL8) and Pentraxin (PTX3) Plasma Level in Sprague-Dawley Rats Fed High-Fat Diet?¡ 34035808 |
Nutrients | High Fat, High Sugar Diet and DJOS Bariatric Surgery Influence Plasma Levels of Fetuin-B, Growth Differentiation Factor-15, and Pentraxin 3 in Diet-Induced Obese … 34684637 |
J Obstet Gynaecol Res | Protective effects of dichloroacetic acid on endometrial injury and ovarian reserve in an experimental rat model of diabetes mellitus 34595798 |
Catalog No. | Related products for research use of Mus musculus (Mouse) Organism species | Applications (RESEARCH USE ONLY!) |
RPK411Mu01 | Recombinant Pentraxin 3, Long (PTX3) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAK411Mu01 | Polyclonal Antibody to Pentraxin 3, Long (PTX3) | WB; IHC; ICC; IP. |
SEK411Mu | ELISA Kit for Pentraxin 3, Long (PTX3) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMK411Mu | Multiplex Assay Kit for Pentraxin 3, Long (PTX3) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |