Multiplex Assay Kit for Fibroblast Growth Factor 15 (FGF15) ,etc. by FLIA (Flow Luminescence Immunoassay)
(Note: Up to 8-plex in one testing reaction)
- Product No.LML154Ra
- Organism SpeciesRattus norvegicus (Rat) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodCompetitive Inhibition
- Assay Length1.5h
- Detection Range0.2-200pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.067 pg/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 522
US$ 542
US$ 572
US$ 612
US$ 652
US$ 712
US$ 802
Result
For more details, please contact local distributors! US$ 1003 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Fibroblast Growth Factor 15 (FGF15) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Fibroblast Growth Factor 15 (FGF15) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Fibroblast Growth Factor 15 (FGF15) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Fibroblast Growth Factor 15 (FGF15) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 78-104 | 88 |
EDTA plasma(n=5) | 96-105 | 101 |
heparin plasma(n=5) | 90-98 | 93 |
sodium citrate plasma(n=5) | 94-102 | 98 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Fibroblast Growth Factor 15 (FGF15) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Fibroblast Growth Factor 15 (FGF15) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Fibroblast Growth Factor 15 (FGF15) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 78-102% | 79-104% | 90-97% | 96-103% |
EDTA plasma(n=5) | 90-101% | 78-98% | 90-98% | 80-101% |
heparin plasma(n=5) | 86-93% | 99-105% | 93-101% | 82-94% |
sodium citrate plasma(n=5) | 98-105% | 78-97% | 79-93% | 82-91% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:FGF15) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Endocrinology. | Naringenin Prevents Obesity, Hepatic Steatosis, and Glucose Intolerance in Male Mice Independent of Fibroblast Growth Factor 21 PubMed: 25774553 |
Inflammatory Bowel Diseases | Alterations in Enterohepatic Fgf15 Signaling and Changes in Bile Acid Composition Depend on Localization of Murine Intestinal Inflammation pubmed:27580383 |
J Lipid Res. | Commensal bacteria at the crossroad between cholesterol homeostasis and chronic inflammation in atherosclerosis. pubmed:28130274 |
BMC Endocrine Disorders | The relationship between bile acid concentration, glucagon-like-peptide 1, fibroblast growth factor 15 and bile acid receptors in rats during progression of glucose intolerance 10.1186/s12902-017-0211-5 |
Journal of Physiology and Biochemistry | The ileal FGF15/19 to hepatic FGFR4 axis regulates liver regeneration after partial hepatectomy in mice Pubmed:29468415 |
Developmental Cell | FGF15 Activates Hippo Signaling to Suppress Bile Acid Metabolism and Liver Tumorigenesis Pubmed: 30745141 |
Endocrinology | Interactions between the gravitostat and the fibroblast growth factor system for the regulation of body weight |
Food & Function | Lactoferrin promotes bile acid metabolism and reduces hepatic cholesterol deposition by inhibiting the farnesoid X receptor (FXR)-mediated enterohepatic axis Pubmed: 31626262 |
Journal of Translational Medicine | Gut microbiota from coronary artery disease patients contributes to vascular dysfunction in mice by regulating bile acid metabolism and immune activation Pubmed: 33036625 |
Chin Med | Si-Wu-Tang ameliorates fibrotic liver injury via modulating intestinal microbiota and bile acid homeostasis 34736501 |
Int J Biol Sci | Dynamics of the gut-liver axis in rats with varying fibrosis severity Pubmed:35637968 |