Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for High Temperature Requirement Factor A1 (HTRA1) ,etc. by FLIA (Flow Luminescence Immunoassay)
HtrA; L56; ORF480; PRSS11; HtrA Serine Peptidase 1; Protease,Serine,11; IGFBP5-Protease; High-temperature requirement A serine peptidase 1
(Note: Up to 8-plex in one testing reaction)
- Product No.LML604Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample TypeSerum, plasma and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range1.95-2000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.65 pg/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 480
US$ 499
US$ 527
US$ 564
US$ 601
US$ 656
US$ 739
Result
For more details, please contact local distributors! US$ 924 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of High Temperature Requirement Factor A1 (HTRA1) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between High Temperature Requirement Factor A1 (HTRA1) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant High Temperature Requirement Factor A1 (HTRA1) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of High Temperature Requirement Factor A1 (HTRA1) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 90-104 | 94 |
EDTA plasma(n=5) | 89-102 | 93 |
heparin plasma(n=5) | 84-96 | 92 |
sodium citrate plasma(n=5) | 79-104 | 97 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level High Temperature Requirement Factor A1 (HTRA1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level High Temperature Requirement Factor A1 (HTRA1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of High Temperature Requirement Factor A1 (HTRA1) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 90-101% | 78-89% | 96-103% | 84-105% |
EDTA plasma(n=5) | 98-105% | 78-104% | 93-104% | 79-88% |
heparin plasma(n=5) | 80-96% | 98-105% | 84-92% | 87-101% |
sodium citrate plasma(n=5) | 83-102% | 80-92% | 98-105% | 80-94% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:HTRA1) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Placenta | Alterations of maternal plasma HTRA1 level in preeclampsia complicated by IUGR PubMed: 23083999 |
Placenta | Upregulation of HtrA4 in the placentas of patients with severe pre-eclampsia PubMed: 22964307 |
Exp Gerontol | Association of frailty with the serine protease HtrA1 in older adults Pubmed:27058767 |
International Journal of Clinical and Experimental Pathology | HtrA1 up-regulates expression of MMPs via Erk1/2/Rock-dependent pathways files:ijcep0069706.pdf |
Pregnancy Hypertension | Association between first trimester plasma htra1 level and subsequent preeclampsia: a possible early marker? |
American journal of translational research | HtrA1 upregulates the expression of ADAMTS-5 in HNPCs via the ERK/NF-κB/JNK signaling pathway Pubmed: 31497227 |
J Matern Fetal Neonatal Med | First trimester HtrA1 maternal plasma level and spontaneous preterm birth Pubmed: 32102578 |
BMC Geriatr | Cross-sectional associations among P3NP, HtrA, Hsp70, Apelin and sarcopenia in Taiwanese population 33743591 |
Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
RPL604Hu01 | Recombinant High Temperature Requirement Factor A1 (HTRA1) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAL604Hu01 | Polyclonal Antibody to High Temperature Requirement Factor A1 (HTRA1) | WB; IHC; ICC; IP. |
LAL604Hu71 | Biotin-Linked Polyclonal Antibody to High Temperature Requirement Factor A1 (HTRA1) | WB; IHC; ICC. |
SEL604Hu | ELISA Kit for High Temperature Requirement Factor A1 (HTRA1) | Enzyme-linked immunosorbent assay for Antigen Detection. |
SCL604Hu | CLIA Kit for High Temperature Requirement Factor A1 (HTRA1) | Chemiluminescent immunoassay for Antigen Detection. |
LML604Hu | Multiplex Assay Kit for High Temperature Requirement Factor A1 (HTRA1) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |