Multiplex Assay Kit for NADH Dehydrogenase, Quinone 1 (NQO1) ,etc. by FLIA (Flow Luminescence Immunoassay)
DHQU; DIA4; DTD; NMOR1; NMORI; QR1; Azoreductase; DT-diaphorase; Menadione reductase; Phylloquinone reductase; Quinone reductase 1; NAD(P)H:quinone oxidoreductase 1
(Note: Up to 8-plex in one testing reaction)
- Product No.LML969Ra
- Organism SpeciesRattus norvegicus (Rat) Same name, Different species.
- Sample TypeTissue homogenates, cell lysates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range0.02-20ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.007 ng/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 522
US$ 542
US$ 572
US$ 612
US$ 652
US$ 712
US$ 802
Result
For more details, please contact local distributors! US$ 1003 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of NADH Dehydrogenase, Quinone 1 (NQO1) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between NADH Dehydrogenase, Quinone 1 (NQO1) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant NADH Dehydrogenase, Quinone 1 (NQO1) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of NADH Dehydrogenase, Quinone 1 (NQO1) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 93-101 | 96 |
EDTA plasma(n=5) | 81-99 | 94 |
heparin plasma(n=5) | 94-103 | 99 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level NADH Dehydrogenase, Quinone 1 (NQO1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level NADH Dehydrogenase, Quinone 1 (NQO1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of NADH Dehydrogenase, Quinone 1 (NQO1) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 88-101% | 90-97% | 89-99% | 81-105% |
EDTA plasma(n=5) | 91-101% | 85-101% | 81-92% | 83-90% |
heparin plasma(n=5) | 99-105% | 90-102% | 86-104% | 90-97% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:NQO1) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Hypertension | Transcription factor Nrf2 protects renal dopamine D1 receptor function during oxidative stress. Pubmed: 23876469 |
Free Radical Research | Notoginsenoside R1-mediated neuroprotection involves estrogen receptor-dependent crosstalk between Akt and ERK1/2 pathways: A novel mechanism of Nrf2/ARE signaling activation Informahealthcare: Source |
physiological reports | Antioxidant resveratrol restores renal sodium transport regulation in SHR PubMed: 26603454 |
Biol Chem | Genetic association of NAD (P) H Quinone Oxidoreductase (NQO1* 2) polymorphism with NQO1 levels and risk of diabetic nephropathy Pubmed:27078674 |
Experimental Parasitology | Sodium arsenite augments sensitivity of Echinococcus granulosus protoscoleces to albendazole Pubmed: 30790573 |
International Journal of Nanomedicine | Gold Nanoparticles Perturb Drug-Metabolizing Enzymes and Antioxidants in the Livers of Male Rats: Potential Impact on Drug Interactions Pubmed: 32764932 |
Exp Parasitol | In vitro protoscolicidal effects of lithocholic acid on protoscoleces of Echinococcus granulosus and its mechanism Pubmed:35594934 |
Catalog No. | Related products for research use of Rattus norvegicus (Rat) Organism species | Applications (RESEARCH USE ONLY!) |
RPL969Ra01 | Recombinant NADH Dehydrogenase, Quinone 1 (NQO1) | Positive Control; Immunogen; SDS-PAGE; WB. |
APL969Ra01 | Active NADH Dehydrogenase, Quinone 1 (NQO1) | Cell culture; Activity Assays. |
PAL969Ra01 | Polyclonal Antibody to NADH Dehydrogenase, Quinone 1 (NQO1) | WB; IHC; ICC; IP. |
MAL969Ra21 | Monoclonal Antibody to NADH Dehydrogenase, Quinone 1 (NQO1) | WB; IHC; ICC; IP. |
SEL969Ra | ELISA Kit for NADH Dehydrogenase, Quinone 1 (NQO1) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LML969Ra | Multiplex Assay Kit for NADH Dehydrogenase, Quinone 1 (NQO1) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |