Multiplex Assay Kit for Taurocholic Acid (TCA) ,etc. by FLIA (Flow Luminescence Immunoassay)
Cholaic Acid; Cholyltaurine; Acidum Cholatauricum
(Note: Up to 8-plex in one testing reaction)
- Product No.LMO267Ge
- Organism SpeciesPan-species (General) Same name, Different species.
- Sample TypeBiological fluids
- Test MethodCompetitive Inhibition
- Assay Length1.5h
- Detection Range0.29-300ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.097 ng/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 561
US$ 582
US$ 614
US$ 658
US$ 701
US$ 765
US$ 862
Result
For more details, please contact local distributors! US$ 1078 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Taurocholic Acid (TCA) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Taurocholic Acid (TCA) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Taurocholic Acid (TCA) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Taurocholic Acid (TCA) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:TCA) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.