Multiplex Assay Kit for C1q And Tumor Necrosis Factor Related Protein 9 (C1QTNF9) ,etc. by FLIA (Flow Luminescence Immunoassay)

CTRP9; C1QTNF9A; AQL1; Complement C1q and tumor necrosis factor-related protein 9A

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of C1q And Tumor Necrosis Factor Related Protein 9 (C1QTNF9) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between C1q And Tumor Necrosis Factor Related Protein 9 (C1QTNF9) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant C1q And Tumor Necrosis Factor Related Protein 9 (C1QTNF9) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of C1q And Tumor Necrosis Factor Related Protein 9 (C1QTNF9) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 78-92 85
EDTA plasma(n=5) 85-94 89
heparin plasma(n=5) 97-105 101
sodium citrate plasma(n=5) 93-101 97

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level C1q And Tumor Necrosis Factor Related Protein 9 (C1QTNF9) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level C1q And Tumor Necrosis Factor Related Protein 9 (C1QTNF9) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of C1q And Tumor Necrosis Factor Related Protein 9 (C1QTNF9) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 78-99% 80-97% 84-97% 80-97%
EDTA plasma(n=5) 93-103% 82-91% 80-91% 91-105%
heparin plasma(n=5) 83-97% 86-94% 95-105% 88-102%
sodium citrate plasma(n=5) 97-104% 99-105% 97-105% 90-97%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:C1QTNF9) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Int J Obes (Lond). Association of serum C1q/TNF-Related Protein-9 (CTRP9) concentration with visceral adiposity and metabolic syndrome in humans. Pubmed: 24357853
J Clin Endocrinol Metab.? Association of Serum C1q/TNF-Related Protein-9 Concentration With Arterial Stiffness in Subjects With Type 2 Diabetes Pubmed:25105737
J Clin Endocrinol Metab.  C1q/TNF-Related Protein-9 (CTRP9) Levels Are Associated With Obesity and Decrease Following Weight Loss Surgery Pubmed:26982010
PLoS One. Circulating C1q complement/TNF-related protein (CTRP) 1, CTRP9, CTRP12 and CTRP13 concentrations in Type 2 diabetes mellitus: In vivo regulation by glucose. pubmed:28207876
Journal of Diabetes Research Plasma C1q/TNF-Related Protein-9 Levels Are Associated with Atherosclerosis in Patients withType 2 Diabetes without Renal Dysfunction. pubmed:28070523
diabetes research and clinical practice Circulating CTRP9 levels are increased in patients with newly diagnosed type 2 diabetes and correlated with insulin resistance pubmed:28743061
PLoS One Association of circulating CTRP9 with soluble adhesion molecules and inflammatory markers in patients with type 2 diabetes mellitus and coronary artery … Pubmed:29381773
archives of insect biochemistry and physiology Effect of a single bout of resistance exercise on zinc-α2-glycoprotein Pubmed: 31686532
J Diabetes Investig Association of serum CTRP9 levels with cardiac autonomic neuropathy in patients with type 2 diabetes mellitus 33417302
Neurol Ther Association Between Serum C1q Tumor Necrosis Factor-Related Protein 9 and the Clinical Characteristics and Prognosis of Ischemic Stroke 34727346
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
SER877Mu ELISA Kit for C1q And Tumor Necrosis Factor Related Protein 9 (C1QTNF9) Enzyme-linked immunosorbent assay for Antigen Detection.
LMR877Mu Multiplex Assay Kit for C1q And Tumor Necrosis Factor Related Protein 9 (C1QTNF9) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.