Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Angiopoietin Like Protein 8 (ANGPTL8) ,etc. by FLIA (Flow Luminescence Immunoassay)
RIFL; TD26; C19orf80; Lipasin; Betatrophin; Hepatocellular Carcinoma-Associated Protein TD26
(Note: Up to 8-plex in one testing reaction)
- Product No.LMW803Ra
- Organism SpeciesRattus norvegicus (Rat) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range1.95-2000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.65 pg/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 522
US$ 542
US$ 572
US$ 612
US$ 652
US$ 712
US$ 802
Result
For more details, please contact local distributors! US$ 1003 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Angiopoietin Like Protein 8 (ANGPTL8) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Angiopoietin Like Protein 8 (ANGPTL8) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Angiopoietin Like Protein 8 (ANGPTL8) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Angiopoietin Like Protein 8 (ANGPTL8) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 81-102 | 86 |
EDTA plasma(n=5) | 95-103 | 101 |
heparin plasma(n=5) | 78-90 | 82 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Angiopoietin Like Protein 8 (ANGPTL8) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Angiopoietin Like Protein 8 (ANGPTL8) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Angiopoietin Like Protein 8 (ANGPTL8) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 97-104% | 94-101% | 93-101% | 80-95% |
EDTA plasma(n=5) | 96-105% | 97-104% | 88-101% | 85-96% |
heparin plasma(n=5) | 97-105% | 91-105% | 85-103% | 79-94% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:ANGPTL8) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
PLoS One | Increased Maternal and Cord Blood Betatrophin in Gestational Diabetes PubMed: 26115519 |
Nutrición Hospitalaria | Serum betatrophin level increased in subjects with metabolic syndrome: a case-control study wp-content:10563 |
Mediators of Inflammation | Serum betatrophin level increased in subjects with nonalcoholic fatty liver disease files:ijcem0020951.pdf |
PLoS One | Resolving Discrepant Findings on ANGPTL8 in β-Cell Proliferation: A Collaborative Approach to Resolving the Betatrophin Controversy pubmed:27410263 |
Obesity Research and Clinical Practice | Relationship between serum betatrophin levels and the first-phase of glucose-stimulated insulin secretion pubmed:27554132 |
打不开网页 | Aumento del nivel de betatrofina en suero en sujetos con síndrome metabólico: estudio de casos y controles : |
DIABETES & METABOLISM | Levels of betatrophin decrease during pregnancy despite increased insulin resistance, beta-cellfunction and triglyceride levels. pubmed:27555469 |
Decreased circulating levels of betatrophin in Chinese women with polycystic ovary syndrome : | |
International Journal of Endocrinology | Serum concentrations of betatrophin and its association with indirect indices of insulin resistance and beta cell function in women with polycystic ovary … pubmed:28702052 |
Diabetes Research and Clinical Practice | Angiopoietin-like protein 8: an attractive biomarker for the evaluation of subjects with insulin resistance and related disorders pubmed:28965028 |
Diabetes/Metabolism Research and Reviews | ANGPTL8 (Betatrophin) Role in Diabetes and Metabolic Diseases pubmed:28722798 |
Bibliography | The Correlation Between Circulating Betatrophin and Insulin Resistance in General Population: A Meta-Analysis pubmed:28931172 |
Frontiers in Endocrinology | ANGPTL8: an important regulator in metabolic disorders Pubmed:29719529 |
Nutrients | ChREBP Reciprocally Regulates Liver and Plasma Triacylglycerol Levels in Different Manners Pubmed: 30405056 |
Nature Communications | Angptl8 mediates food-driven resetting of hepatic circadian clock in mice Pubmed: 31388006 |
Journal of Immunology Research | The Impact of Psoriasis and Metabolic Syndrome on the Systemic Inflammation and Oxidative Damage to Nucleic Acids Pubmed: 32537470 |
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM | Genetic and Metabolic Determinants of Plasma Levels of ANGPTL8 33619548 |
Medicine | Association of betatrophin amounts with 25-(OH) D levels in patients with gestational diabetes mellitus 33879746 |
International Journal of Endocrinology | Effect of Ileal Transposition (IT) on Angiopoietin-Like Protein-8 (ANGPTL8) and Pentraxin (PTX3) Plasma Level in Sprague-Dawley Rats Fed High-Fat Diet?¡ 34035808 |
Catalog No. | Related products for research use of Rattus norvegicus (Rat) Organism species | Applications (RESEARCH USE ONLY!) |
SEW803Ra | ELISA Kit for Angiopoietin Like Protein 8 (ANGPTL8) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMW803Ra | Multiplex Assay Kit for Angiopoietin Like Protein 8 (ANGPTL8) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |