Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Mini Samples ELISA Kit for Interleukin 23 Subunit Alpha (IL23a)
P19; IL23P19; SGRF
- Product No.MEA384Mu
- Organism SpeciesMus musculus (Mouse) Same name, Different species.
- Sample Typeserum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3h
- Detection Range7.8-500pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 2.9pg/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 374
For more details, please contact local distributors! US$ 534 US$ 2403 US$ 4539 US$ 37380
Specificity
This assay has high sensitivity and excellent specificity for detection of Mini Samples Interleukin 23 Subunit Alpha (IL23a).
No significant cross-reactivity or interference between Mini Samples Interleukin 23 Subunit Alpha (IL23a) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Mini Samples Interleukin 23 Subunit Alpha (IL23a) and the recovery rates were calculated by comparing the measured value to the expected amount of Mini Samples Interleukin 23 Subunit Alpha (IL23a) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 81-101 | 93 |
EDTA plasma(n=5) | 97-105 | 102 |
heparin plasma(n=5) | 96-104 | 101 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Mini Samples Interleukin 23 Subunit Alpha (IL23a) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mini Samples Interleukin 23 Subunit Alpha (IL23a) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Mini Samples Interleukin 23 Subunit Alpha (IL23a) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 78-97% | 82-101% | 78-95% | 96-104% |
EDTA plasma(n=5) | 79-93% | 87-95% | 89-101% | 83-91% |
heparin plasma(n=5) | 84-96% | 89-101% | 89-97% | 86-101% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×60µL | Assay Diluent A | 1×6mL |
Detection Reagent B | 1×60µL | Assay Diluent B | 1×6mL |
TMB Substrate | 1×4.5mL | Stop Solution | 1×3mL |
Wash Buffer (30 × concentrate) | 1×10mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 25µL standard or sample to each well. Incubate 1 hour at 37°C;
3. Aspirate and add 25µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 25µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 25µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 20µL Stop Solution. Read at 450nm immediately.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Biogerontology | Aging affects AO rat splenic conventional dendritic cell subset composition, cytokine synthesis and T-helper polarizing capacity Pubmed: 23873152 |
Molecular Medicine Reports | Tanshinone IIA attenuates experimental autoimmune encephalomyelitis in rats Pubmed:27357729 |
J Endod. | Multiple Apical Periodontitis Influences Serum Levels of Cytokines and Nitric Oxide Pubmed:27059651 |
International Immunopharmacology | Estradiol enhances capacity of TLR-matured splenic dendritic cells to polarize CD4+lymphocytes into IL-17/GM-CSF-producing cells in vitro. pubmed:27620506 |
Biology of Reproduction | Recombinant adiponectin alleviates abortion in mice by regulating Th17/Treg imbalance via p38MAPK-STAT5 pathway Pubmed: 30496353 |
BMC MICROBIOLOGY | Enhanced antifungal activity of bovine lactoferrin-producing probiotic Lactobacillus casei in the murine model of vulvovaginal candidiasis Pubmed: 30621597 |
Biogerontology | Age and sex determine CD4+ T cell stimulatory and polarizing capacity of rat splenic dendritic cells Pubmed: 31646402 |
Biomed Research International | Effects of 2, 3, 7, 8-Tetrachlorodibenzo-p-dioxin on T Cell Differentiation in Primary Biliary Cholangitis Pubmed: 32908870 |
J Periodontol | Cytokine profile in serum and gingival crevicular fluid of children with inflammatory bowel disease: A case‐control study 34730850 |
Catalog No. | Related products for research use of Mus musculus (Mouse) Organism species | Applications (RESEARCH USE ONLY!) |
RPA384Mu01 | Recombinant Interleukin 23 Subunit Alpha (IL23a) | Positive Control; Immunogen; SDS-PAGE; WB. |
RPA384Mu02 | Recombinant Interleukin 23 Subunit Alpha (IL23a) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA384Mu02 | Polyclonal Antibody to Interleukin 23 Subunit Alpha (IL23a) | WB; IHC; ICC; IP. |
PAA384Mu01 | Polyclonal Antibody to Interleukin 23 Subunit Alpha (IL23a) | WB; IHC; ICC; IP. |
MEA384Mu | Mini Samples ELISA Kit for Interleukin 23 Subunit Alpha (IL23a) | Enzyme-linked immunosorbent assay for Antigen Detection. |
SEA384Mu | ELISA Kit for Interleukin 23 Subunit Alpha (IL23a) | Enzyme-linked immunosorbent assay for Antigen Detection. |
SCA384Mu | CLIA Kit for Interleukin 23 Subunit Alpha (IL23a) | Chemiluminescent immunoassay for Antigen Detection. |
LMA384Mu | Multiplex Assay Kit for Interleukin 23 Subunit Alpha (IL23a) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |