Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Mini Samples ELISA Kit for Estrone (E1)
Oestrone
- Product No.MEB003Ge
- Organism SpeciesPan-species (General) Same name, Different species.
- Sample Typeserum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodCompetitive Inhibition
- Assay Length3h
- Detection Range24.69-2,000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 9.09pg/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 679
For more details, please contact local distributors! US$ 970 US$ 4365 US$ 8245 US$ 67900
Specificity
This assay has high sensitivity and excellent specificity for detection of Mini Samples Estrone (E1).
No significant cross-reactivity or interference between Mini Samples Estrone (E1) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of Mini Samples Estrone (E1) and the recovery rates were calculated by comparing the measured value to the expected amount of Mini Samples Estrone (E1) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 91-101 | 94 |
EDTA plasma(n=5) | 82-103 | 87 |
heparin plasma(n=5) | 82-102 | 86 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Mini Samples Estrone (E1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mini Samples Estrone (E1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Mini Samples Estrone (E1) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 89-101% | 80-93% | 83-95% | 92-99% |
EDTA plasma(n=5) | 97-105% | 95-102% | 90-97% | 87-99% |
heparin plasma(n=5) | 92-104% | 94-102% | 98-105% | 93-101% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
And then add 50µL prepared Detection Reagent A immediately.
Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 50µL Stop Solution. Read at 450 nm immediately.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Plos One | Association between Polycystic Ovary Syndrome and Cavia (Guinea pig )t Microbiota Pubmed:27093642 |
African Journal of Environmental Science and Technology | Pollution by endocrine disrupting estrogens in aquatic ecosystems in Morogoro urban and peri-urban areas in Tanzania 150659 |
African Journal of Environmental Science and Technology | Pollution by endocrine disrupting estrogens in aquatic ecosystems in Morogoro urban and peri-urban areas in Tanzania 10.5897/AJEST2016.2234 |
Talanta | Phosphorescent palladium-tetrabenzoporphyrin indicators for immunosensing of small molecules with a novel optical device 33379126 |
Catalog No. | Related products for research use of Pan-species (General) Organism species | Applications (RESEARCH USE ONLY!) |
CPB003Ge11 | BSA Conjugated Estrone (E1) | Immunogen; SDS-PAGE; WB. |
CPB003Ge21 | OVA Conjugated Estrone (E1) | Immunogen; SDS-PAGE; WB. |
PAB003Ge01 | Polyclonal Antibody to Estrone (E1) | ELISA, CLIA. / IHC-Fr, ICC, IP (predicted). |
PAB003Ge02 | Polyclonal Antibody to Estrone (E1) | ELISA, CLIA. / IHC-Fr, ICC, IP (predicted). |
MAB003Ge21 | Monoclonal Antibody to Estrone (E1) | ELISA, CLIA. / IHC-Fr, ICC, IP (predicted). |
MEB003Ge | Mini Samples ELISA Kit for Estrone (E1) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CEB003Ge | ELISA Kit for Estrone (E1) | Enzyme-linked immunosorbent assay for Antigen Detection. |
IEB003Ge | Instant ELISA Kit for Estrone (E1) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CCB003Ge | CLIA Kit for Estrone (E1) | Chemiluminescent immunoassay for Antigen Detection. |
LMB003Ge | Multiplex Assay Kit for Estrone (E1) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
PSB003Ge11 | Antibody Pair for Estrone (E1) | ELISA; CLIA; ELISPOT; Luminex; Immunochromatography and other Immunoassays. |
KSB003Ge11 | ELISA Kit DIY Materials for Estrone (E1) | Main materials for "Do It (ELISA Kit) Yourself". |