Mini Samples ELISA Kit for Fibroblast Growth Factor 18 (FGF18)

ZFGF5

Specificity

This assay has high sensitivity and excellent specificity for detection of Mini Samples Fibroblast Growth Factor 18 (FGF18).
No significant cross-reactivity or interference between Mini Samples Fibroblast Growth Factor 18 (FGF18) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Mini Samples Fibroblast Growth Factor 18 (FGF18) and the recovery rates were calculated by comparing the measured value to the expected amount of Mini Samples Fibroblast Growth Factor 18 (FGF18) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 92-99 95
EDTA plasma(n=5) 92-105 101
heparin plasma(n=5) 86-98 94

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Mini Samples Fibroblast Growth Factor 18 (FGF18) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mini Samples Fibroblast Growth Factor 18 (FGF18) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Mini Samples Fibroblast Growth Factor 18 (FGF18) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 80-96% 94-103% 79-105% 78-102%
EDTA plasma(n=5) 93-102% 78-88% 96-103% 78-102%
heparin plasma(n=5) 96-103% 96-105% 93-101% 82-94%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×60µL Assay Diluent A 1×6mL
Detection Reagent B 1×60µL Assay Diluent B 1×6mL
TMB Substrate 1×4.5mL Stop Solution 1×3mL
Wash Buffer (30 × concentrate) 1×10mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 25µL standard or sample to each well. Incubate 1 hour at 37°C;
3. Aspirate and add 25µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 25µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 25µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 20µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Pesqui. Bras. Odontopediatria Clín. Integr Human Umbilical Cord Mesenchymal Stem Cells Over Platelet Rich Fibrin Scaffold for Mandibular Cartilage Defects Regenerative Medicine
J Exp Clin Cancer Res HDAC7 promotes NSCLC proliferation and metastasis via stabilization by deubiquitinase USP10 and activation of β-catenin-FGF18 pathway Pubmed:35277183
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
RPC907Mu01 Recombinant Fibroblast Growth Factor 18 (FGF18) Positive Control; Immunogen; SDS-PAGE; WB.
RPC907Mu02 Recombinant Fibroblast Growth Factor 18 (FGF18) Positive Control; Immunogen; SDS-PAGE; WB.
PAC907Mu01 Polyclonal Antibody to Fibroblast Growth Factor 18 (FGF18) WB; IHC; ICC; IP.
PAC907Mu02 Polyclonal Antibody to Fibroblast Growth Factor 18 (FGF18) WB; IHC; ICC; IP.
MEC907Mu Mini Samples ELISA Kit for Fibroblast Growth Factor 18 (FGF18) Enzyme-linked immunosorbent assay for Antigen Detection.
SEC907Mu ELISA Kit for Fibroblast Growth Factor 18 (FGF18) Enzyme-linked immunosorbent assay for Antigen Detection.
SCC907Mu CLIA Kit for Fibroblast Growth Factor 18 (FGF18) Chemiluminescent immunoassay for Antigen Detection.
LMC907Mu Multiplex Assay Kit for Fibroblast Growth Factor 18 (FGF18) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.