Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Mini Samples ELISA Kit for Sequestosome 1 (SQSTM1)
OSIL; PDB3; ZIP3; p62; p62B; p60; A170; Paget Disease Of Bone 3; Oxidative Stress Induced Like; EBI3-associated protein of 60 kDa; Ubiquitin-binding protein p62
- Product No.MED198Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample TypeTissue homogenates, cell lysates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3h
- Detection Range0.312-20ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.114ng/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 588
For more details, please contact local distributors! US$ 840 US$ 3780 US$ 7140 US$ 58800
Specificity
This assay has high sensitivity and excellent specificity for detection of Mini Samples Sequestosome 1 (SQSTM1).
No significant cross-reactivity or interference between Mini Samples Sequestosome 1 (SQSTM1) and analogues was observed.
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Mini Samples Sequestosome 1 (SQSTM1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mini Samples Sequestosome 1 (SQSTM1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×60µL | Assay Diluent A | 1×6mL |
Detection Reagent B | 1×60µL | Assay Diluent B | 1×6mL |
TMB Substrate | 1×4.5mL | Stop Solution | 1×3mL |
Wash Buffer (30 × concentrate) | 1×10mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 25µL standard or sample to each well. Incubate 1 hour at 37°C;
3. Aspirate and add 25µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 25µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 25µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 20µL Stop Solution. Read at 450nm immediately.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
BRIEFINGS IN BIOINFORMATICS | Lysosome activation in peripheral blood mononuclear cells and prognostic significance of circulating LC3B in COVID-19 33620066 |
BIOMARKERS OF AUTOPHAGY AND ANTIVIRAL ROLE OF PLACENTA FOR PREDICTING PRETERM DELIVERY IN PATIENTS WITH PRETERM DELIVERY?¡ |