Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Mini Samples ELISA Kit for Homocysteine (HCy)
- Product No.MED984Ge
- Organism SpeciesPan-species (General) Same name, Different species.
- Sample Typeserum, plasma and other biological fluids
- Test MethodCompetitive Inhibition
- Assay Length3h
- Detection Range98.77-8,000ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 33.52ng/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 685
For more details, please contact local distributors! US$ 979 US$ 4406 US$ 8322 US$ 68530
Specificity
This assay has high sensitivity and excellent specificity for detection of Mini Samples Homocysteine (HCy).
No significant cross-reactivity or interference between Mini Samples Homocysteine (HCy) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of Mini Samples Homocysteine (HCy) and the recovery rates were calculated by comparing the measured value to the expected amount of Mini Samples Homocysteine (HCy) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 86-93 | 90 |
EDTA plasma(n=5) | 86-102 | 95 |
heparin plasma(n=5) | 83-94 | 89 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Mini Samples Homocysteine (HCy) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mini Samples Homocysteine (HCy) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Mini Samples Homocysteine (HCy) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 95-103% | 78-89% | 78-94% | 85-92% |
EDTA plasma(n=5) | 87-98% | 94-101% | 88-105% | 87-101% |
heparin plasma(n=5) | 93-101% | 78-97% | 82-96% | 86-105% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×60µL | Assay Diluent A | 1×6mL |
Detection Reagent B | 1×60µL | Assay Diluent B | 1×6mL |
TMB Substrate | 1×9mL | Stop Solution | 1×3mL |
Wash Buffer (30 × concentrate) | 1×10mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 25µL standard or sample to each well.
And then add 25μL prepared Detection Reagent A immediately.
Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 50µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 50µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 25µL Stop Solution. Read at 450 nm immediately.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Journal of Developmental Origins of Health and Disease | Maternal low-quality protein diet exerts sex-specific effects on plasma amino acid profile and alters hepatic expression of methyltransferases in adult rat offspring Pubmed:29582727 |
The Scientific Journal of Al-Azhar Medical Faculty, Girls | Homocysteinemia in relation to anemia in hypothyroid patients Doi: 10.4103/sjamf.sjamf_31_18 |
Science of The Total Environment | Organochlorine pesticides exposure may disturb homocysteine metabolism in pregnant women Pubmed: 31787282 |
AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH | Baicalin rescues hyperglycemia-induced neural tube defects via targeting on retinoic acid signaling Pubmed: 32774702 |
Journal of Diabetes Research | Changes and Risk Factors of Skeletal Muscle Mass and Strength in Patients with Type 2 Diabetes over 60 Years Old: A Cross-Sectional Study from China |
Journal of Advances in Medical and Pharmaceutical Sciences | Homocysteinaemia in Heart Failure Patients in North Eastern Nigeria |
Obstetrik ve Neonatoloji T?p Dergisi | KARD?YOVASK¨¹LER S?STEM HASTALIKLARINDA R?SK FAKT?R¨¹ OLAN H?PERHOMOS?STE?NEM?'N?N POL?K?ST?K OVER SENDROMUNDAK? YER? |
Frontiers in Nutrition | Folate, Vitamin B12, and Homocysteine Levels in Women With Neural Tube Defect-Affected Pregnancy in Addis Ababa, Ethiopia Pubmed:35464038 |
Catalog No. | Related products for research use of Pan-species (General) Organism species | Applications (RESEARCH USE ONLY!) |
CPD984Ge11 | BSA Conjugated Homocysteine (HCy) | Immunogen; SDS-PAGE; WB. |
CPD984Ge21 | OVA Conjugated Homocysteine (HCy) | Immunogen; SDS-PAGE; WB. |
PAD984Ge01 | Polyclonal Antibody to Homocysteine (HCy) | ELISA, CLIA. / IHC-Fr, ICC, IP (predicted). |
MED984Ge | Mini Samples ELISA Kit for Homocysteine (HCy) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CED984Ge | ELISA Kit for Homocysteine (HCy) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMD984Ge | Multiplex Assay Kit for Homocysteine (HCy) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
KSD984Ge11 | ELISA Kit DIY Materials for Homocysteine (HCy) | Main materials for "Do It (ELISA Kit) Yourself". |