Mini Samples ELISA Kit for Interleukin 1 Zeta (IL1z)

IL1F7; IL37; FIL1; FIL1(ZETA); FIL1Z; IL-1F7; IL-1H4; IL-1RP1; IL1H4; IL1RP1; Interleukin 37; Interleukin-1-Related Protein; Interleukin 1 Family, Member 7

Specificity

This assay has high sensitivity and excellent specificity for detection of Mini Samples Interleukin 1 Zeta (IL1z).
No significant cross-reactivity or interference between Mini Samples Interleukin 1 Zeta (IL1z) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Mini Samples Interleukin 1 Zeta (IL1z) and the recovery rates were calculated by comparing the measured value to the expected amount of Mini Samples Interleukin 1 Zeta (IL1z) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 99-105 102
EDTA plasma(n=5) 88-99 92
heparin plasma(n=5) 97-105 101

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Mini Samples Interleukin 1 Zeta (IL1z) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mini Samples Interleukin 1 Zeta (IL1z) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Mini Samples Interleukin 1 Zeta (IL1z) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 98-105% 89-102% 85-97% 88-99%
EDTA plasma(n=5) 97-104% 92-99% 88-97% 95-103%
heparin plasma(n=5) 81-101% 87-101% 85-92% 88-95%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Journal of Periodontal Research Levels of interleukin-37 in gingival crevicular fluid, saliva, or plasma in periodontal disease Pubmed:25399716
Arthritis research & therapy Interleukin 37 limits monosodium urate crystal-induced innate immune responses in human and murine models of gout. pubmed:27863506
Thoracic Cancer  IL‐37 inhibits invasion and metastasis in non‐small cell lung cancer by suppressing the IL‐6/STAT3 signaling pathway Pubmed:29575809