CLIA Kit for Eosinophil Chemotactic Factor (ECF)

CCL11; SCYA11; Eotaxin 1; Eosinophil Chemotactic Protein 1; Chemokine C-C-Motif Ligand 11; Small Inducible Cytokine Subfamily A(Cys-Cys)Member 11

Specificity

This assay has high sensitivity and excellent specificity for detection of Eosinophil Chemotactic Factor (ECF).
No significant cross-reactivity or interference between Eosinophil Chemotactic Factor (ECF) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Eosinophil Chemotactic Factor (ECF) and the recovery rates were calculated by comparing the measured value to the expected amount of Eosinophil Chemotactic Factor (ECF) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 98-105 101
EDTA plasma(n=5) 88-102 93
heparin plasma(n=5) 91-103 95

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Eosinophil Chemotactic Factor (ECF) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Eosinophil Chemotactic Factor (ECF) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Eosinophil Chemotactic Factor (ECF) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 78-102% 82-96% 83-101% 94-101%
EDTA plasma(n=5) 88-103% 90-103% 84-93% 78-94%
heparin plasma(n=5) 89-98% 82-97% 93-101% 85-93%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
Substrate A 1×10mL Substrate B 1×2mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
INTERNATIONAL ARCHIVES OF ALLERGY AND IMMUNOLOGY Elevated Serum Level of CD48 in Patients with Intermittent Allergic Rhinitis Pubmed: 32966985
Exp Mol Pathol The regulatory role of SFRP5/WNT5A axis in allergic rhinitis through inhibiting JNK pathway activation and lowering mucin generation in human nasal?¡­ 33285209
Immunopharmacol Immunotoxicol sCD48 is elevated in non-allergic but not in allergic persistent rhinitis 34477021
Exp Eye Res Sulforaphane inhibits cytokine-stimulated chemokine and adhesion molecule expressions in human corneal fibroblasts: Involvement of the MAPK, STAT, and NF-κB … Pubmed:35038457
Catalog No. Related products for research use of Equus caballus; Equine (Horse) Organism species Applications (RESEARCH USE ONLY!)
RPA025Eq01 Recombinant Eosinophil Chemotactic Factor (ECF) Positive Control; Immunogen; SDS-PAGE; WB.
PAA025Eq01 Polyclonal Antibody to Eosinophil Chemotactic Factor (ECF) WB; IHC; ICC; IP.
MAA025Eq21 Monoclonal Antibody to Eosinophil Chemotactic Factor (ECF) WB; IHC; ICC; IP.
SEA025Eq ELISA Kit for Eosinophil Chemotactic Factor (ECF) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA025Eq CLIA Kit for Eosinophil Chemotactic Factor (ECF) Chemiluminescent immunoassay for Antigen Detection.
LMA025Eq Multiplex Assay Kit for Eosinophil Chemotactic Factor (ECF) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.