Packages (Simulation)
Reagent Preparation
Image (I)
Certificate
CLIA Kit for Matrix Metalloproteinase 10 (MMP10)
STMY2; SL2; Stromelysin 2; Transin-2
- Product No.SCA098Ra
- Organism SpeciesRattus norvegicus (Rat) Same name, Different species.
- Sample TypeSerum, plasma and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length2h, 40min
- Detection Range6.86-5,000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 2.89pg/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 638
For more details, please contact local distributors! US$ 912 US$ 4104 US$ 7752 US$ 63840
Specificity
This assay has high sensitivity and excellent specificity for detection of Matrix Metalloproteinase 10 (MMP10).
No significant cross-reactivity or interference between Matrix Metalloproteinase 10 (MMP10) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Matrix Metalloproteinase 10 (MMP10) and the recovery rates were calculated by comparing the measured value to the expected amount of Matrix Metalloproteinase 10 (MMP10) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 88-96 | 93 |
EDTA plasma(n=5) | 78-102 | 82 |
heparin plasma(n=5) | 83-98 | 92 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Matrix Metalloproteinase 10 (MMP10) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Matrix Metalloproteinase 10 (MMP10) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Matrix Metalloproteinase 10 (MMP10) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 91-99% | 89-96% | 86-103% | 94-102% |
EDTA plasma(n=5) | 87-94% | 82-93% | 95-102% | 78-95% |
heparin plasma(n=5) | 80-101% | 84-98% | 96-105% | 97-104% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
Substrate A | 1×10mL | Substrate B | 1×2mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.
GIVEAWAYS
INCREMENT SERVICES
- Single-component Reagents of Assay Kit
- Lysis Buffer Specific for ELISA / CLIA
- Quality Control of Kit
- CLIA Kit Customized Service
- Disease Model Customized Service
- Serums Customized Service
- TGFB1 Activation Reagent
- Real Time PCR Experimental Service
- Streptavidin
- Fast blue Protein Stain solution
- Single-component Reagents of FLIA Kit
- Streptavidin-Agarose Beads
Magazine | Citations |
Journal of Cellular and Molecular Medicine | Type-specific dysregulation of matrix metalloproteinases and their tissue inhibitors in end-stage heart failure patients: relationship between MMP-10 and LV remodelling Wiley: source |
PLoS One. | Matrix Metalloproteinase-10 Is Required for Lung Cancer Stem Cell Maintenance, Tumor Initiation and Metastatic Potential PubMed: PMC3335833 |
PLoS ONE | A Combinatorial Relative Mass Value Evaluation of Endogenous Bioactive Proteins in Three-Dimensional Cultured Nucleus Pulposus Cells of Herniated Intervertebral Discs: Identification of Potential Target Proteins for Gene Therapeutic Approaches Plosone: Source |
Thromb Haemost. | Analysis of the expression of nine secreted matrix metalloproteinases and their endogenous inhibitors in the brain of mice subjected to ischaemic stroke Pubmed:24671655 |
Brain, Behavior, and Immunity | Plasma inflammatory biomarkers for Huntington’s disease patients and mouse model Pubmed:25266150 |
Biomedical Materials | In vivo bioengineered ovarian tumors based on collagen, matrigel, alginate and agarose hydrogels: a comparative study Pubmed:25634132 |
Brain, Behavior, and Immunity | Plasma inflammatory biomarkers for Huntington’s disease patients and mouse model PubMed: 25266150 |
Catalog No. | Related products for research use of Rattus norvegicus (Rat) Organism species | Applications (RESEARCH USE ONLY!) |
RPA098Ra01 | Recombinant Matrix Metalloproteinase 10 (MMP10) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA098Ra01 | Polyclonal Antibody to Matrix Metalloproteinase 10 (MMP10) | WB; IHC; ICC; IP. |
MAA098Ra21 | Monoclonal Antibody to Matrix Metalloproteinase 10 (MMP10) | WB; IHC; ICC; IP. |
SEA098Ra | ELISA Kit for Matrix Metalloproteinase 10 (MMP10) | Enzyme-linked immunosorbent assay for Antigen Detection. |
SCA098Ra | CLIA Kit for Matrix Metalloproteinase 10 (MMP10) | Chemiluminescent immunoassay for Antigen Detection. |
LMA098Ra | Multiplex Assay Kit for Matrix Metalloproteinase 10 (MMP10) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |