Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
CLIA Kit for Platelet Derived Growth Factor AB (PDGFAB)
PDGF-AB
- Product No.SCA436Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length2h, 40min
- Detection Range27.4-20,000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 12.7pg/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 588
For more details, please contact local distributors! US$ 840 US$ 3780 US$ 7140 US$ 58800
Specificity
This assay has high sensitivity and excellent specificity for detection of Platelet Derived Growth Factor AB (PDGFAB).
No significant cross-reactivity or interference between Platelet Derived Growth Factor AB (PDGFAB) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Platelet Derived Growth Factor AB (PDGFAB) and the recovery rates were calculated by comparing the measured value to the expected amount of Platelet Derived Growth Factor AB (PDGFAB) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 88-98 | 91 |
EDTA plasma(n=5) | 80-104 | 97 |
heparin plasma(n=5) | 89-102 | 96 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Platelet Derived Growth Factor AB (PDGFAB) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Platelet Derived Growth Factor AB (PDGFAB) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Platelet Derived Growth Factor AB (PDGFAB) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 98-105% | 78-99% | 90-104% | 81-94% |
EDTA plasma(n=5) | 91-99% | 79-105% | 80-94% | 87-101% |
heparin plasma(n=5) | 83-92% | 97-105% | 82-90% | 94-105% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
Substrate A | 1×10mL | Substrate B | 1×2mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
PeerJ | Platelet-rich concentrate in serum free medium enhances osteogenic differentiation of bone marrow-derived human mesenchymal stromal cells pubmed:27651984 |
Materials Science & Engineering C-Materials for Biological Applications | Effect of crystalline phase changes in titania (TiO2) nanotube coatings on platelet adhesion and activation Pubmed:29025678 |
EXPERIMENTAL GERONTOLOGY | The application of thermal oscillation method to augment the effectiveness of autologous platelet rich plasma in treating elderly patients with knee osteoarthritis Pubmed: 33091524 |
Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
SEA436Hu | ELISA Kit for Platelet Derived Growth Factor AB (PDGFAB) | Enzyme-linked immunosorbent assay for Antigen Detection. |
SCA436Hu | CLIA Kit for Platelet Derived Growth Factor AB (PDGFAB) | Chemiluminescent immunoassay for Antigen Detection. |
LMA436Hu | Multiplex Assay Kit for Platelet Derived Growth Factor AB (PDGFAB) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |