CLIA Kit for Glucokinase (GCK)

GK; GLK; HHF3; HK4; HKIV; HXKP; MODY2; Hexokinase-D; Hexokinase 4; Maturity Onset Diabetes Of The Young 2

Specificity

This assay has high sensitivity and excellent specificity for detection of Glucokinase (GCK).
No significant cross-reactivity or interference between Glucokinase (GCK) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Glucokinase (GCK) and the recovery rates were calculated by comparing the measured value to the expected amount of Glucokinase (GCK) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 93-101 96
EDTA plasma(n=5) 96-105 101
heparin plasma(n=5) 94-102 97

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Glucokinase (GCK) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Glucokinase (GCK) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Glucokinase (GCK) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 80-104% 95-103% 94-101% 96-104%
EDTA plasma(n=5) 99-105% 87-101% 92-105% 93-101%
heparin plasma(n=5) 89-101% 78-98% 83-95% 93-101%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
Substrate A 1×10mL Substrate B 1×2mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Life Sciences Vitamin C and E chronic supplementation differentially affect hepatic insulin signaling in rats Pubmed:29291420
Food & Function Hypoglycemic effects of wheat bran alkyresorcinols in high-fat/high-sucrose diet and low-dose streptozotocin-induced type 2 diabetic male mice and protection of … Pubmed: 31094396
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPA667Hu01 Recombinant Glucokinase (GCK) Positive Control; Immunogen; SDS-PAGE; WB.
PAA667Hu01 Polyclonal Antibody to Glucokinase (GCK) WB; IHC; ICC; IP.
LAA667Hu71 Biotin-Linked Polyclonal Antibody to Glucokinase (GCK) WB; IHC; ICC.
MAA667Hu22 Monoclonal Antibody to Glucokinase (GCK) WB; IHC; ICC; IP.
SEA667Hu ELISA Kit for Glucokinase (GCK) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA667Hu CLIA Kit for Glucokinase (GCK) Chemiluminescent immunoassay for Antigen Detection.
LMA667Hu Multiplex Assay Kit for Glucokinase (GCK) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.