CLIA Kit for High Density Lipoprotein (HDL)
- Product No.SCB006Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample Typeserum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length2h, 40min
- Detection Range0.206-150ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.093ng/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 588
For more details, please contact local distributors! US$ 840 US$ 3780 US$ 7140 US$ 58800
Specificity
This assay has high sensitivity and excellent specificity for detection of High Density Lipoprotein (HDL).
No significant cross-reactivity or interference between High Density Lipoprotein (HDL) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant High Density Lipoprotein (HDL) and the recovery rates were calculated by comparing the measured value to the expected amount of High Density Lipoprotein (HDL) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 78-103 | 99 |
EDTA plasma(n=5) | 92-101 | 95 |
heparin plasma(n=5) | 84-98 | 89 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level High Density Lipoprotein (HDL) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level High Density Lipoprotein (HDL) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of High Density Lipoprotein (HDL) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 89-98% | 86-95% | 82-91% | 93-101% |
EDTA plasma(n=5) | 91-101% | 80-95% | 85-92% | 94-103% |
heparin plasma(n=5) | 82-101% | 80-101% | 85-92% | 88-102% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
Substrate A | 1×10mL | Substrate B | 1×2mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Iranian Journal of Health and Physical activity | Effects of Aerobic Training, with or without Zizyphus Jujuba Water Extraction, on Fundus Nesfatin-1, ATP, HDL-C, and LDL-C Concentrations in Female Rats Ijvst: Source |
Scandinavian Journal of Medicine & Science in Sports | Endurance training selectively increases HDL-bound sphingosine-1-phosphate in the plasma pubmed:28493600 |
Journal of Nutritional Science and Vitaminology (Tokyo) | Anthocyanin Cyanidin-3-Glucoside Attenuates Platelet Granule Release in Mice Fed High-Fat Diets. pubmed:28978870 |
RESPIRATORY RESEARCH | The HDL from septic-ARDS patients with composition changes exacerbates pulmonary endothelial dysfunction and acute lung injury induced by cecal ligation … Pubmed: 33148285 |
respiratory research | The adverse alterations of HDL in quality promote septic ARDS via exacerbated pulmonary endothelial dysfunction |
Diabetes Metab Syndr Obes | ¡°Adjusting Internal Organs and Dredging Channel¡± Electroacupuncture Ameliorates Insulin Resistance in Type 2 Diabetes Mellitus by Regulating the Intestinal?¡ 34135611 |
Evid Based Complement Alternat Med | Effect of Acupoint Embedding on Serum Leptin and Hypothalamus Leptin Receptor Expression in Rats with Simple Obesity 34659432 |
Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
PAB006Hu01 | Polyclonal Antibody to High Density Lipoprotein (HDL) | WB; IHC; ICC; IP. |
LAB006Hu71 | Biotin-Linked Polyclonal Antibody to High Density Lipoprotein (HDL) | WB; IHC; ICC. |
SEB006Hu | ELISA Kit for High Density Lipoprotein (HDL) | Enzyme-linked immunosorbent assay for Antigen Detection. |
SCB006Hu | CLIA Kit for High Density Lipoprotein (HDL) | Chemiluminescent immunoassay for Antigen Detection. |
LMB006Hu | Multiplex Assay Kit for High Density Lipoprotein (HDL) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
KSB006Hu01 | ELISA Kit DIY Materials for High Density Lipoprotein (HDL) | Main materials for "Do It (ELISA Kit) Yourself". |