CLIA Kit for Monokine Induced By Interferon Gamma (MIg)

CXCL9; CMK; Humig; MI-G; SCYB9; Crg-10; Chemokine (C-X-C motif) ligand 9; Small-inducible cytokine B9; Gamma-interferon-induced monokine

Specificity

This assay has high sensitivity and excellent specificity for detection of Monokine Induced By Interferon Gamma (MIg).
No significant cross-reactivity or interference between Monokine Induced By Interferon Gamma (MIg) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Monokine Induced By Interferon Gamma (MIg) and the recovery rates were calculated by comparing the measured value to the expected amount of Monokine Induced By Interferon Gamma (MIg) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 83-99 94
EDTA plasma(n=5) 91-99 95
heparin plasma(n=5) 80-104 83

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Monokine Induced By Interferon Gamma (MIg) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Monokine Induced By Interferon Gamma (MIg) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Monokine Induced By Interferon Gamma (MIg) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 85-104% 93-105% 81-101% 81-97%
EDTA plasma(n=5) 78-97% 88-99% 79-105% 82-91%
heparin plasma(n=5) 97-105% 93-105% 93-101% 79-101%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
Substrate A 1×10mL Substrate B 1×2mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
PLoS One. The Transcription Factor C/EBP delta Has Anti-Apoptotic and Anti-Inflammatory Roles in Pancreatic Beta Cells PubMed: PMC3275575
International Journal of Chronic Obstructive Pulmonary Disease High Blood Eosinophil and YKL-40 Levels, as Well as Low CXCL9 Levels, are Associated with Increased Readmission in Patients with Acute Exacerbation of Chronic Obstructive Pulmonary Disease 33814903
Catalog No. Related products for research use of Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
RPB928Ra01 Recombinant Monokine Induced By Interferon Gamma (MIg) Positive Control; Immunogen; SDS-PAGE; WB.
PAB928Ra01 Polyclonal Antibody to Monokine Induced By Interferon Gamma (MIg) WB; IHC; ICC; IP.
MAB928Ra21 Monoclonal Antibody to Monokine Induced By Interferon Gamma (MIg) WB; IHC; ICC; IP.
SEB928Ra ELISA Kit for Monokine Induced By Interferon Gamma (MIg) Enzyme-linked immunosorbent assay for Antigen Detection.
SCB928Ra CLIA Kit for Monokine Induced By Interferon Gamma (MIg) Chemiluminescent immunoassay for Antigen Detection.
LMB928Ra Multiplex Assay Kit for Monokine Induced By Interferon Gamma (MIg) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.