CLIA Kit for Methionine Adenosyltransferase I Alpha (MAT1a)

MAT; SAMS; MATA1; SAMS1; AMS1; S-Adenosylmethionine Synthetase; S-adenosylmethionine synthase isoform type-1

Specificity

This assay has high sensitivity and excellent specificity for detection of Methionine Adenosyltransferase I Alpha (MAT1a).
No significant cross-reactivity or interference between Methionine Adenosyltransferase I Alpha (MAT1a) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Methionine Adenosyltransferase I Alpha (MAT1a) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Methionine Adenosyltransferase I Alpha (MAT1a) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
Substrate A 1×10mL Substrate B 1×2mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

GIVEAWAYS

INCREMENT SERVICES

Catalog No. Related products for research use of Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
RPG470Ra01 Recombinant Methionine Adenosyltransferase I Alpha (MAT1a) Positive Control; Immunogen; SDS-PAGE; WB.
PAG470Ra01 Polyclonal Antibody to Methionine Adenosyltransferase I Alpha (MAT1a) WB; IHC; ICC; IP.
MAG470Ra21 Monoclonal Antibody to Methionine Adenosyltransferase I Alpha (MAT1a) WB; IHC; ICC; IP.
SEG470Ra ELISA Kit for Methionine Adenosyltransferase I Alpha (MAT1a) Enzyme-linked immunosorbent assay for Antigen Detection.
SCG470Ra CLIA Kit for Methionine Adenosyltransferase I Alpha (MAT1a) Chemiluminescent immunoassay for Antigen Detection.
LMG470Ra Multiplex Assay Kit for Methionine Adenosyltransferase I Alpha (MAT1a) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.