ELISA Kit for Immunoglobulin G4 (IgG4)

IGHG4; Ig Gamma-4 Chain C Region; Immunoglobulin Heavy Constant Gamma 4; G4m Marker; Immunoglobulin Gm4

Specificity

This assay has high sensitivity and excellent specificity for detection of Immunoglobulin G4 (IgG4).
No significant cross-reactivity or interference between Immunoglobulin G4 (IgG4) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Immunoglobulin G4 (IgG4) and the recovery rates were calculated by comparing the measured value to the expected amount of Immunoglobulin G4 (IgG4) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 81-89 84
EDTA plasma(n=5) 84-92 89
heparin plasma(n=5) 97-104 101

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Immunoglobulin G4 (IgG4) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Immunoglobulin G4 (IgG4) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Immunoglobulin G4 (IgG4) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 94-102% 92-99% 81-99% 99-105%
EDTA plasma(n=5) 78-101% 95-102% 95-103% 81-101%
heparin plasma(n=5) 92-103% 87-95% 95-105% 78-95%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
BioMed Research International The Effect of CXC Motif Chemokine 13 on Hepatocellular Carcinoma Associates with Wnt Signaling Hindawi:Source
Adv Med Sci. Utility of serum IgG, IgG4 and carbonic anhydrase II antibodies in distinguishing autoimmune pancreatitis from pancreatic cancer and chronic pancreatitis Pubmed:25194335
Oncology Reports Beneficial effect of T follicular helper cells on antibody class switching of B cells in prostate cancer Pubmed:25529861
Iranian Journal of Pharmaceutical Research Effect of Cysteamine on Cell Growth and IgG4 Production in Recombinant Sp2.0 Cells Pubmed:25561924
Ann Hematol Loss of interleukin-21 leads to atrophic germinal centers in multicentric Castleman’s disease PubMed: 26377996
Biomed Res Int The Effect of C-X-C Motif Chemokine 13 on Hepatocellular Carcinoma Associates with Wnt Signaling PubMed: 26161394
网页进不去,NCBI上搜不到 Increasing Foxp3, IgG4 and improvement quality of life after immunotherapy treatment in allergic rhinitis patients article:30785
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
NPA234Hu01 Native Immunoglobulin G4 (IgG4) Positive Control; Immunogen; SDS-PAGE; WB.
RPA234Hu01 Recombinant Immunoglobulin G4 (IgG4) Positive Control; Immunogen; SDS-PAGE; WB.
CPA234Hu21 OVA Conjugated Immunoglobulin G4 (IgG4) Immunogen; SDS-PAGE; WB.
CPA234Hu31 KLH Conjugated Immunoglobulin G4 (IgG4) Immunogen; SDS-PAGE; WB.
PAA234Hu02 Polyclonal Antibody to Immunoglobulin G4 (IgG4) WB; IHC; ICC; IP.
PAA234Hu01 Polyclonal Antibody to Immunoglobulin G4 (IgG4) WB; IHC
PAA234Hu08 Polyclonal Antibody to Immunoglobulin G4 (IgG4) WB; IHC; ICC; IP.
PAA234Hu03 Polyclonal Antibody to Immunoglobulin G4 (IgG4) WB; IHC; ICC; IP.
LAA234Hu71 Biotin-Linked Polyclonal Antibody to Immunoglobulin G4 (IgG4) WB; IHC; ICC.
LAA234Hu81 FITC-Linked Polyclonal Antibody to Immunoglobulin G4 (IgG4) WB; IHC; ICC; IF.
MAA234Hu22 Monoclonal Antibody to Immunoglobulin G4 (IgG4) WB
MAA234Hu23 Monoclonal Antibody to Immunoglobulin G4 (IgG4) WB; IHC; ICC; IP.
MAA234Hu24 Monoclonal Antibody to Immunoglobulin G4 (IgG4) WB; IHC; ICC; IP.
MAA234Hu21 Monoclonal Antibody to Immunoglobulin G4 (IgG4) WB; IHC; ICC; IP.
LAA234Hu72 Biotin-Linked Monoclonal Antibody to Immunoglobulin G4 (IgG4) WB; IHC; ICC.
LAA234Hu82 FITC-Linked Monoclonal Antibody to Immunoglobulin G4 (IgG4) WB; IHC; ICC; IF.
SEA234Hu ELISA Kit for Immunoglobulin G4 (IgG4) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA234Hu Multiplex Assay Kit for Immunoglobulin G4 (IgG4) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA234Hu01 ELISA Kit DIY Materials for Immunoglobulin G4 (IgG4) Main materials for "Do It (ELISA Kit) Yourself".