Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
ELISA Kit for Proteolipid Protein 1, Myelin (PLP1)
MMPL; PLP/DM20; PMD; SPG2; Pelizaeus-Merzbacher Disease; Spastic Paraplegia 2,Uncomplicated; Myelin proteolipid protein; Lipophilin
- Product No.SEA417Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample Typetissue homogenates, cell lysates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3h
- Detection Range0.156-10ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.062ng/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 441
For more details, please contact local distributors! US$ 630 US$ 2835 US$ 5355 US$ 44100
Specificity
This assay has high sensitivity and excellent specificity for detection of Proteolipid Protein 1, Myelin (PLP1).
No significant cross-reactivity or interference between Proteolipid Protein 1, Myelin (PLP1) and analogues was observed.
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Proteolipid Protein 1, Myelin (PLP1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Proteolipid Protein 1, Myelin (PLP1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
GIVEAWAYS
INCREMENT SERVICES
- Single-component Reagents of Assay Kit
- Lysis Buffer Specific for ELISA / CLIA
- Quality Control of Kit
- ELISA Kit Customized Service
- Disease Model Customized Service
- Serums Customized Service
- TGFB1 Activation Reagent
- Real Time PCR Experimental Service
- Streptavidin
- Fast blue Protein Stain solution
- Single-component Reagents of FLIA Kit
- Streptavidin-Agarose Beads
Magazine | Citations |
Brain Pathology | Pathophysiology of Hypoperfusion of the Precuneus in Early Alzheimer's Disease PubMed: 26452729 |
Alzheimers Research & Therapy | Visual hallucinations in Alzheimer's disease do not seem to be associated with chronic hypoperfusion of to visual processing areas V2 and V3 but may be … Pubmed: 31511061 |
Brain Pathol | Mediators of cerebral hypoperfusion and blood©\brain barrier leakiness in alzheimer's disease, vascular dementia and mixed dementia 33410232 |
Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
RPA417Hu01 | Recombinant Proteolipid Protein 1, Myelin (PLP1) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA417Hu01 | Polyclonal Antibody to Proteolipid Protein 1, Myelin (PLP1) | WB; IHC; ICC; IP. |
MAA417Hu21 | Monoclonal Antibody to Proteolipid Protein 1, Myelin (PLP1) | WB; IHC; ICC; IP. |
SEA417Hu | ELISA Kit for Proteolipid Protein 1, Myelin (PLP1) | Enzyme-linked immunosorbent assay for Antigen Detection. |
AEA417Hu | ELISA Kit for Anti-Proteolipid Protein 1, Myelin Antibody (Anti-PLP1) | Enzyme-linked immunosorbent assay for Antibody Detection. |