Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
ELISA Kit for Actin Alpha 1, Skeletal Muscle (ACTa1)
ACT-A1; ASMA; CFTD; CFTD1; CFTDM; MPFD; NEM1; NEM2; NEM3
- Product No.SEB634Mi
- Organism SpeciesHomo sapiens (Human), Mus musculus (Mouse), Rattus norvegicus (Rat) Same name, Different species.
- Sample TypeTissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3h
- Detection Range1.56-100ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.59ng/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 479
For more details, please contact local distributors! US$ 684 US$ 3078 US$ 5814 US$ 47880
Specificity
This assay has high sensitivity for detection of Actin Alpha 1, Skeletal Muscle (ACTa1).
100% cross-reactivity of Actin Alpha 1, Skeletal Muscle (ACTa1) was observed among Human, Mouse, Rat.
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Actin Alpha 1, Skeletal Muscle (ACTa1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Actin Alpha 1, Skeletal Muscle (ACTa1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
GIVEAWAYS
INCREMENT SERVICES
- Single-component Reagents of Assay Kit
- Lysis Buffer Specific for ELISA / CLIA
- Quality Control of Kit
- ELISA Kit Customized Service
- Disease Model Customized Service
- Serums Customized Service
- TGFB1 Activation Reagent
- Real Time PCR Experimental Service
- Streptavidin
- Fast blue Protein Stain solution
- Single-component Reagents of FLIA Kit
- Streptavidin-Agarose Beads
Magazine | Citations |
J Physiol Pharmacol. | Fibrogenic response of hepatic stellate cells in ovarectomised rats exposed to ketogenic diet Pubmed: 23568967 |
Catalog No. | Related products for research use of Homo sapiens (Human), Mus musculus (Mouse), Rattus norvegicus (Rat) Organism species | Applications (RESEARCH USE ONLY!) |
RPB634Mi01 | Recombinant Actin Alpha 1, Skeletal Muscle (ACTa1) | Positive Control; Immunogen; SDS-PAGE; WB. |
SEB634Mi | ELISA Kit for Actin Alpha 1, Skeletal Muscle (ACTa1) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMB634Mi | Multiplex Assay Kit for Actin Alpha 1, Skeletal Muscle (ACTa1) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |