ELISA Kit for Lymphocyte Activation Gene 3 (LAG3)

CD223; Protein FDC

Specificity

This assay has high sensitivity and excellent specificity for detection of Lymphocyte Activation Gene 3 (LAG3).
No significant cross-reactivity or interference between Lymphocyte Activation Gene 3 (LAG3) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Lymphocyte Activation Gene 3 (LAG3) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Lymphocyte Activation Gene 3 (LAG3) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Biosensors and Bioelectronics A signal-decreased electrochemical immunosensor for the sensitive detection of LAG-3 protein based on a hollow nanobox-MOFs/AuPt alloy Pubmed:29772383
Cancer Biomarkers Soluble LAG3 acts as a potential prognostic marker of gastric cancer and its positive correlation with CD8+ T cell frequency and secretion of IL-12 and INF-γ in … Pubmed: 30223387
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
RPB663Mu02 Recombinant Lymphocyte Activation Gene 3 (LAG3) Positive Control; Immunogen; SDS-PAGE; WB.
RPB663Mu01 Recombinant Lymphocyte Activation Gene 3 (LAG3) Positive Control; Immunogen; SDS-PAGE; WB.
EPB663Mu61 Eukaryotic Lymphocyte Activation Gene 3 (LAG3) Positive Control; Immunogen; SDS-PAGE; WB.
APB663Mu61 Active Lymphocyte Activation Gene 3 (LAG3) Cell culture; Activity Assays.
PAB663Mu01 Polyclonal Antibody to Lymphocyte Activation Gene 3 (LAG3) WB; IHC; ICC; IP.
SEB663Mu ELISA Kit for Lymphocyte Activation Gene 3 (LAG3) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB663Mu Multiplex Assay Kit for Lymphocyte Activation Gene 3 (LAG3) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.