ELISA Kit for Vinculin (VCL)

MVCL; Metavinculin

Specificity

This assay has high sensitivity and excellent specificity for detection of Vinculin (VCL).
No significant cross-reactivity or interference between Vinculin (VCL) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Vinculin (VCL) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Vinculin (VCL) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
PBMCs S-NO proteomic signature in heart failure S-Nitrosylation Proteome Profile of Peripheral Blood Mononuclear Cells in Human Heart Failure journals:1384523
J Cell Sci PCTAIRE1 promotes mitotic progression and resistance against antimitotic and apoptotic signals Pubmed:35044463
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPB839Hu01 Recombinant Vinculin (VCL) Positive Control; Immunogen; SDS-PAGE; WB.
RPB839Hu02 Recombinant Vinculin (VCL) Positive Control; Immunogen; SDS-PAGE; WB.
PAB839Hu01 Polyclonal Antibody to Vinculin (VCL) WB; IHC; ICC; IP.
PAB839Hu02 Polyclonal Antibody to Vinculin (VCL) WB; IHC; ICC; IP.
CAB839Hu01 Anti-Vinculin (VCL) Polyclonal Antibody Loading Control of WB.
LAB839Hu71 Biotin-Linked Polyclonal Antibody to Vinculin (VCL) WB; IHC; ICC.
MAB839Hu22 Monoclonal Antibody to Vinculin (VCL) WB; IHC; ICC; IP.
MAB839Hu21 Monoclonal Antibody to Vinculin (VCL) WB; IHC; ICC; IP.
CAB839Hu22 Anti-Vinculin (VCL) Monoclonal Antibody Loading Control of WB
SEB839Hu ELISA Kit for Vinculin (VCL) Enzyme-linked immunosorbent assay for Antigen Detection.
AEB839Hu ELISA Kit for Anti-Vinculin Antibody (Anti-VCL) Enzyme-linked immunosorbent assay for Antibody Detection.
LMB839Hu Multiplex Assay Kit for Vinculin (VCL) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.