ELISA Kit for Major Histocompatibility Complex Class I A (MHCA)

HLA-A; HLAA; MHC-A; Leukocyte Antigen A; HLA class I histocompatibility antigen, A-31 alpha chain

Specificity

This assay has high sensitivity and excellent specificity for detection of Major Histocompatibility Complex Class I A (MHCA).
No significant cross-reactivity or interference between Major Histocompatibility Complex Class I A (MHCA) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Major Histocompatibility Complex Class I A (MHCA) and the recovery rates were calculated by comparing the measured value to the expected amount of Major Histocompatibility Complex Class I A (MHCA) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 98-105 101
EDTA plasma(n=5) 94-101 97
heparin plasma(n=5) 98-105 101

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Major Histocompatibility Complex Class I A (MHCA) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Major Histocompatibility Complex Class I A (MHCA) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Major Histocompatibility Complex Class I A (MHCA) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 83-95% 97-104% 92-99% 84-94%
EDTA plasma(n=5) 79-94% 78-97% 80-99% 84-91%
heparin plasma(n=5) 83-95% 80-105% 83-101% 83-98%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
BMJ Open Sport & Exercise Medicine Two-peaked increase of serum myosin heavy chain-α after triathlon suggests heart muscle cell death Pubmed: 30740234
Aerobic capacity predicts skeletal but not cardiac muscle damage after a full distance Ironman triathlon-the Iron (wo) man-study
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPC085Hu01 Recombinant Major Histocompatibility Complex Class I A (MHCA) Positive Control; Immunogen; SDS-PAGE; WB.
PAC085Hu01 Polyclonal Antibody to Major Histocompatibility Complex Class I A (MHCA) WB; IHC; ICC; IP.
MAC085Hu21 Monoclonal Antibody to Major Histocompatibility Complex Class I A (MHCA) WB; IHC; ICC; IP.
SEC085Hu ELISA Kit for Major Histocompatibility Complex Class I A (MHCA) Enzyme-linked immunosorbent assay for Antigen Detection.
LMC085Hu Multiplex Assay Kit for Major Histocompatibility Complex Class I A (MHCA) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.