Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
ELISA Kit for Syncollin (SYCN)
SYL; INSSA1; Insulin Synthesis Associated 1
- Product No.SED879Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3h
- Detection Range0.156-10ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.059ng/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 490
For more details, please contact local distributors! US$ 700 US$ 3150 US$ 5950 US$ 49000
Specificity
This assay has high sensitivity and excellent specificity for detection of Syncollin (SYCN).
No significant cross-reactivity or interference between Syncollin (SYCN) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Syncollin (SYCN) and the recovery rates were calculated by comparing the measured value to the expected amount of Syncollin (SYCN) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 83-97 | 93 |
EDTA plasma(n=5) | 79-88 | 83 |
heparin plasma(n=5) | 93-101 | 98 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Syncollin (SYCN) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Syncollin (SYCN) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Syncollin (SYCN) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 78-96% | 89-96% | 82-91% | 84-91% |
EDTA plasma(n=5) | 78-97% | 97-105% | 85-103% | 80-89% |
heparin plasma(n=5) | 79-94% | 86-101% | 88-105% | 94-102% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
GIVEAWAYS
INCREMENT SERVICES
- Single-component Reagents of Assay Kit
- Lysis Buffer Specific for ELISA / CLIA
- Quality Control of Kit
- ELISA Kit Customized Service
- Disease Model Customized Service
- Serums Customized Service
- TGFB1 Activation Reagent
- Real Time PCR Experimental Service
- Streptavidin
- Fast blue Protein Stain solution
- Single-component Reagents of FLIA Kit
- Streptavidin-Agarose Beads
Magazine | Citations |
Molecular & Cellular Proteomics | Integrated Proteomic Profiling of Cell Line Conditioned Media and Pancreatic Juice for the Identification of Pancreatic Cancer Biomarkers PubMed: PMC3205865 |
BMC Cancer. | Validation of four candidate pancreatic cancer serological biomarkers that improve the performance of CA19.10 Pubmed: 24007603 |
Clinical Cancer Research | Validation of Biomarkers That Complement CA19.9 in Detecting Early Pancreatic Cancer Pubmed:25239611 |
Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
RPD879Hu01 | Recombinant Syncollin (SYCN) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAD879Hu01 | Polyclonal Antibody to Syncollin (SYCN) | WB; IHC; ICC; IP. |
MAD879Hu21 | Monoclonal Antibody to Syncollin (SYCN) | WB; IHC; ICC; IP. |
SED879Hu | ELISA Kit for Syncollin (SYCN) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMD879Hu | Multiplex Assay Kit for Syncollin (SYCN) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |