ELISA Kit for Neurofilament, Light Polypeptide (NEFL)
CMT1F; CMT2E; NF-L; NF68; NFL; 68 kDa neurofilament protein; Neurofilament triplet L protein
- Product No.SEE038Bo
- Organism SpeciesBos taurus; Bovine (Cattle) Same name, Different species.
- Sample Typeserum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3h
- Detection Range15.6-1,000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 5.9pg/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 588
For more details, please contact local distributors! US$ 840 US$ 3780 US$ 7140 US$ 58800
Specificity
This assay has high sensitivity and excellent specificity for detection of Neurofilament, Light Polypeptide (NEFL).
No significant cross-reactivity or interference between Neurofilament, Light Polypeptide (NEFL) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Neurofilament, Light Polypeptide (NEFL) and the recovery rates were calculated by comparing the measured value to the expected amount of Neurofilament, Light Polypeptide (NEFL) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 95-104 | 101 |
EDTA plasma(n=5) | 80-90 | 83 |
heparin plasma(n=5) | 85-97 | 89 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Neurofilament, Light Polypeptide (NEFL) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Neurofilament, Light Polypeptide (NEFL) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Neurofilament, Light Polypeptide (NEFL) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 78-95% | 89-103% | 82-93% | 78-95% |
EDTA plasma(n=5) | 88-102% | 80-94% | 80-90% | 92-102% |
heparin plasma(n=5) | 87-102% | 97-104% | 85-92% | 89-98% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
GIVEAWAYS
INCREMENT SERVICES
- Single-component Reagents of Assay Kit
- Lysis Buffer Specific for ELISA / CLIA
- Quality Control of Kit
- ELISA Kit Customized Service
- Disease Model Customized Service
- Serums Customized Service
- TGFB1 Activation Reagent
- Real Time PCR Experimental Service
- Streptavidin
- Fast blue Protein Stain solution
- Single-component Reagents of FLIA Kit
- Streptavidin-Agarose Beads
Magazine | Citations |
Acta Neurologica Scandinavica | Effect of carotid endarterectomy on brain damage markers Pubmed:27126899 |
Acta Neurologica Scandinavica | Effect of carotid endarterectomy on brain damage markers. pubmed:27126899 |
journal of neuroimmunology | Cytokines and biological markers in autoimmune GFAP astrocytopathy: The potential role for pathogenesis and therapeutic implications Pubmed: 31254929 |
Cerebellum | Neurofilament Light Chain Is a Biomarker of Neurodegeneration in Ataxia Telangiectasia 33893614 |
Medicine (Baltimore) | Phase 1b dose-escalation, safety, and pharmacokinetic study of IC14, a monoclonal antibody against CD14, for the treatment of amyotrophic lateral sclerosis 34678870 |
J Clin Med | Fatty Acid-Binding Protein 7 (FABP-7), Glutamic Acid and Neurofilament Light Chain (NFL) as Potential Markers of Neurodegenerative Disorders in Psoriatic Patients … Pubmed:35566558 |
Catalog No. | Related products for research use of Bos taurus; Bovine (Cattle) Organism species | Applications (RESEARCH USE ONLY!) |
SEE038Bo | ELISA Kit for Neurofilament, Light Polypeptide (NEFL) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LME038Bo | Multiplex Assay Kit for Neurofilament, Light Polypeptide (NEFL) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |