Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
ELISA Kit for Glycoprotein 2, Zymogen Granule Membrane (GP2)
ZAP75; Pancreatic Secretory Granule Membrane Major Glycoprotein GP2; Pancreatic zymogen granule membrane protein GP-2
- Product No.SEE569Ra
- Organism SpeciesRattus norvegicus (Rat) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates and other biological fluids.
- Test MethodDouble-antibody Sandwich
- Assay Length3h
- Detection Range0.312-20ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.122ng/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 532
For more details, please contact local distributors! US$ 760 US$ 3420 US$ 6460 US$ 53200
Specificity
This assay has high sensitivity and excellent specificity for detection of Glycoprotein 2, Zymogen Granule Membrane (GP2).
No significant cross-reactivity or interference between Glycoprotein 2, Zymogen Granule Membrane (GP2) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Glycoprotein 2, Zymogen Granule Membrane (GP2) and the recovery rates were calculated by comparing the measured value to the expected amount of Glycoprotein 2, Zymogen Granule Membrane (GP2) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 95-102 | 99 |
EDTA plasma(n=5) | 95-103 | 99 |
heparin plasma(n=5) | 82-101 | 92 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Glycoprotein 2, Zymogen Granule Membrane (GP2) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Glycoprotein 2, Zymogen Granule Membrane (GP2) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Glycoprotein 2, Zymogen Granule Membrane (GP2) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 79-94% | 88-97% | 90-98% | 90-98% |
EDTA plasma(n=5) | 96-105% | 94-102% | 94-102% | 94-102% |
heparin plasma(n=5) | 90-97% | 93-103% | 98-105% | 90-98% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
GIVEAWAYS
INCREMENT SERVICES
- Single-component Reagents of Assay Kit
- Lysis Buffer Specific for ELISA / CLIA
- Quality Control of Kit
- ELISA Kit Customized Service
- Disease Model Customized Service
- Serums Customized Service
- TGFB1 Activation Reagent
- Real Time PCR Experimental Service
- Streptavidin
- Fast blue Protein Stain solution
- Single-component Reagents of FLIA Kit
- Streptavidin-Agarose Beads
Catalog No. | Related products for research use of Rattus norvegicus (Rat) Organism species | Applications (RESEARCH USE ONLY!) |
RPE569Ra01 | Recombinant Glycoprotein 2, Zymogen Granule Membrane (GP2) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAE569Ra01 | Polyclonal Antibody to Glycoprotein 2, Zymogen Granule Membrane (GP2) | WB; IHC; ICC; IP. |
MAE569Ra21 | Monoclonal Antibody to Glycoprotein 2, Zymogen Granule Membrane (GP2) | WB; IHC; ICC; IP. |
MAE569Ra22 | Monoclonal Antibody to Glycoprotein 2, Zymogen Granule Membrane (GP2) | WB; IHC; ICC; IP. |
SEE569Ra | ELISA Kit for Glycoprotein 2, Zymogen Granule Membrane (GP2) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LME569Ra | Multiplex Assay Kit for Glycoprotein 2, Zymogen Granule Membrane (GP2) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |