ELISA Kit for Transcription Termination Factor, RNA polymerase I (TTF1)

RNA polymerase I termination factor

Specificity

This assay has high sensitivity and excellent specificity for detection of Transcription Termination Factor, RNA polymerase I (TTF1).
No significant cross-reactivity or interference between Transcription Termination Factor, RNA polymerase I (TTF1) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Transcription Termination Factor, RNA polymerase I (TTF1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Transcription Termination Factor, RNA polymerase I (TTF1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Acta Pharmaceutica Sinica B Molecularly engineered truncated tissue factor with therapeutic aptamers for tumor-targeted delivery and vascular infarction
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPG777Hu01 Recombinant Transcription Termination Factor, RNA polymerase I (TTF1) Positive Control; Immunogen; SDS-PAGE; WB.
RPG777Hu03 Recombinant Transcription Termination Factor, RNA polymerase I (TTF1) Positive Control; Immunogen; SDS-PAGE; WB.
RPG777Hu02 Recombinant Transcription Termination Factor, RNA polymerase I (TTF1) Positive Control; Immunogen; SDS-PAGE; WB.
CPG777Hu21 OVA Conjugated Transcription Termination Factor, RNA polymerase I (TTF1) Immunogen; SDS-PAGE; WB.
PAG777Hu01 Polyclonal Antibody to Transcription Termination Factor, RNA polymerase I (TTF1) WB; IHC; ICC; IP.
PAG777Hu02 Polyclonal Antibody to Transcription Termination Factor, RNA polymerase I (TTF1) WB; IHC; ICC; IP.
MAG777Hu21 Monoclonal Antibody to Transcription Termination Factor, RNA polymerase I (TTF1) WB; IHC; ICC; IP.
SEG777Hu ELISA Kit for Transcription Termination Factor, RNA polymerase I (TTF1) Enzyme-linked immunosorbent assay for Antigen Detection.
LMG777Hu Multiplex Assay Kit for Transcription Termination Factor, RNA polymerase I (TTF1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.