ELISA Kit for BMP Binding Endothelial Regulator (BMPER)

Cv2; CRIM3; Crossveinless-2; Bone morphogenetic protein-binding endothelial cell precursor-derived regulator

Specificity

This assay has high sensitivity and excellent specificity for detection of BMP Binding Endothelial Regulator (BMPER).
No significant cross-reactivity or interference between BMP Binding Endothelial Regulator (BMPER) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant BMP Binding Endothelial Regulator (BMPER) and the recovery rates were calculated by comparing the measured value to the expected amount of BMP Binding Endothelial Regulator (BMPER) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 98-105 101
EDTA plasma(n=5) 90-98 94
heparin plasma(n=5) 90-102 99

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level BMP Binding Endothelial Regulator (BMPER) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level BMP Binding Endothelial Regulator (BMPER) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of BMP Binding Endothelial Regulator (BMPER) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 78-95% 92-101% 88-95% 96-103%
EDTA plasma(n=5) 90-102% 80-102% 80-93% 93-101%
heparin plasma(n=5) 78-96% 82-94% 78-101% 98-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Journal of Gastroenterology Bone morphogenetic protein-binding endothelial regulator of liver sinusoidal endothelial cellsinduces iron overload in a fatty liver mouse model. pubmed:27364348
JOURNAL OF CELLULAR PHYSIOLOGY BMPER is upregulated in obesity and seems to have a role in pericardial adipose stem cells Pubmed: 32468615
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPJ548Hu01 Recombinant BMP Binding Endothelial Regulator (BMPER) Positive Control; Immunogen; SDS-PAGE; WB.
PAJ548Hu01 Polyclonal Antibody to BMP Binding Endothelial Regulator (BMPER) Applications: WB; IHC; ICC; IP.
MAJ548Hu21 Monoclonal Antibody to BMP Binding Endothelial Regulator (BMPER) WB; IHC; ICC; IP.
SEJ548Hu ELISA Kit for BMP Binding Endothelial Regulator (BMPER) Enzyme-linked immunosorbent assay for Antigen Detection.
LMJ548Hu Multiplex Assay Kit for BMP Binding Endothelial Regulator (BMPER) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.