ELISA Kit for Semaphorin 3C (SEMA3C)

SEMAE; SemE; Semaphorin-E; Sema Domain,Immunoglobulin Domain(Ig),Transmembrane Domain(TM)and Short Cytoplasmic Domain 3C

Specificity

This assay has high sensitivity and excellent specificity for detection of Semaphorin 3C (SEMA3C).
No significant cross-reactivity or interference between Semaphorin 3C (SEMA3C) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Semaphorin 3C (SEMA3C) and the recovery rates were calculated by comparing the measured value to the expected amount of Semaphorin 3C (SEMA3C) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 95-102 99
EDTA plasma(n=5) 87-99 96
heparin plasma(n=5) 93-105 101

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Semaphorin 3C (SEMA3C) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Semaphorin 3C (SEMA3C) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Semaphorin 3C (SEMA3C) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 90-101% 83-104% 81-98% 91-101%
EDTA plasma(n=5) 93-101% 83-97% 78-98% 95-105%
heparin plasma(n=5) 97-104% 95-103% 91-98% 87-101%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Tissue Engineering Part A Semaphorin 3C released from a biocompatible hydrogel Cavia (Guinea pig )ides and promotes axonal growth of rodent and human dopaminergic neurons Pubmed:27174503
Molecular Neurobiology Reduced Sympathetic Innervation in Endometriosis is Associated to Semaphorin 3C and 3FExpression. pubmed:27558236
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPL919Hu01 Recombinant Semaphorin 3C (SEMA3C) Positive Control; Immunogen; SDS-PAGE; WB.
PAL919Hu01 Polyclonal Antibody to Semaphorin 3C (SEMA3C) WB; IHC; ICC; IP.
LAL919Hu71 Biotin-Linked Polyclonal Antibody to Semaphorin 3C (SEMA3C) WB; IHC; ICC.
MAL919Hu21 Monoclonal Antibody to Semaphorin 3C (SEMA3C) WB; IHC; ICC; IP.
SEL919Hu ELISA Kit for Semaphorin 3C (SEMA3C) Enzyme-linked immunosorbent assay for Antigen Detection.
LML919Hu Multiplex Assay Kit for Semaphorin 3C (SEMA3C) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.