ELISA Kit for A Disintegrin And Metalloprotease 33 (ADAM33)

C20orf153; Disintegrin and metalloproteinase domain-containing protein 33

Specificity

This assay has high sensitivity and excellent specificity for detection of A Disintegrin And Metalloprotease 33 (ADAM33).
No significant cross-reactivity or interference between A Disintegrin And Metalloprotease 33 (ADAM33) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level A Disintegrin And Metalloprotease 33 (ADAM33) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level A Disintegrin And Metalloprotease 33 (ADAM33) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Clinical and Experimental Allergy The relationship of airway structural changes to blood and bronchoalveolar lavage biomarkers, and lung function abnormalities in asthma Pubmed: 31532863
journal of investigational allergology and clinical immunology Endothelial dysfunction and pentraxin-3 in clinically stable adult asthma patients Pubmed: 32376513
International Journal of Molecular Sciences Reticular Basement Membrane Thickness Is Associated with Growth-and Fibrosis-Promoting Airway Transcriptome Profile-Study in Asthma Patients 33498209
Integration of Airway In
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPP196Hu01 Recombinant A Disintegrin And Metalloprotease 33 (ADAM33) Positive Control; Immunogen; SDS-PAGE; WB.
PAP196Hu01 Polyclonal Antibody to A Disintegrin And Metalloprotease 33 (ADAM33) WB; IHC; ICC; IP.
MAP196Hu21 Monoclonal Antibody to A Disintegrin And Metalloprotease 33 (ADAM33) WB; IHC; ICC; IP.
SEP196Hu ELISA Kit for A Disintegrin And Metalloprotease 33 (ADAM33) Enzyme-linked immunosorbent assay for Antigen Detection.
LMP196Hu Multiplex Assay Kit for A Disintegrin And Metalloprotease 33 (ADAM33) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.