ELISA Kit for NADH Dehydrogenase 5 (ND5)

MT-ND5; MTND5; NAD5; NADH-Ubiquinone Oxidoreductase Chain 5; Mitochondrially Encoded NADH Dehydrogenase 5

Specificity

This assay has high sensitivity and excellent specificity for detection of NADH Dehydrogenase 5 (ND5).
No significant cross-reactivity or interference between NADH Dehydrogenase 5 (ND5) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant NADH Dehydrogenase 5 (ND5) and the recovery rates were calculated by comparing the measured value to the expected amount of NADH Dehydrogenase 5 (ND5) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 80-90 86
EDTA plasma(n=5) 86-95 90
heparin plasma(n=5) 98-105 101

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level NADH Dehydrogenase 5 (ND5) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level NADH Dehydrogenase 5 (ND5) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of NADH Dehydrogenase 5 (ND5) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 98-105% 78-101% 88-101% 94-104%
EDTA plasma(n=5) 79-98% 90-103% 97-105% 85-92%
heparin plasma(n=5) 83-96% 95-105% 85-98% 88-95%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Andrologia. In vitro antoxidant effect of curcumin on human sperm quality in leucocytospermia doi:10.1111
Andrologia In vitro antioxidant effect of curcumin on human sperm quality in leucocytospermia pubmed:28133770
American journal of reproductive immunology In vitro antioxidation effect of Quercetin on sperm function from the infertile patients with leukocytospermia Pubmed: 31166052
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPS952Hu01 Recombinant NADH Dehydrogenase 5 (ND5) Positive Control; Immunogen; SDS-PAGE; WB.
PAS952Hu01 Polyclonal Antibody to NADH Dehydrogenase 5 (ND5) WB; IHC; ICC; IP.
MAS952Hu21 Monoclonal Antibody to NADH Dehydrogenase 5 (ND5) WB; IHC; ICC; IP.
SES952Hu ELISA Kit for NADH Dehydrogenase 5 (ND5) Enzyme-linked immunosorbent assay for Antigen Detection.
LMS952Hu Multiplex Assay Kit for NADH Dehydrogenase 5 (ND5) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.