CLIA Kit for Hemoglobin (HB)
Hgb; Haemoglobin; Heterotetramer(αβ)2
- Product No.CCB409Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates, erythrocyte lysates, cell culture supernates and other biological fluids
- Test MethodCompetitive Inhibition
- Assay Length2h
- Detection Range1.17-300ug/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.42ug/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 588
For more details, please contact local distributors! US$ 840 US$ 3780 US$ 7140 US$ 58800
Specificity
This assay has high sensitivity and excellent specificity for detection of Hemoglobin (HB).
No significant cross-reactivity or interference between Hemoglobin (HB) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Hemoglobin (HB) and the recovery rates were calculated by comparing the measured value to the expected amount of Hemoglobin (HB) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 88-102 | 98 |
EDTA plasma(n=5) | 85-99 | 94 |
heparin plasma(n=5) | 80-101 | 90 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Hemoglobin (HB) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Hemoglobin (HB) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Hemoglobin (HB) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 94-105% | 96-105% | 78-89% | 87-101% |
EDTA plasma(n=5) | 78-96% | 82-96% | 80-101% | 83-103% |
heparin plasma(n=5) | 97-105% | 85-94% | 97-104% | 97-104% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
Substrate A | 1×10mL | Substrate B | 1×2mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
And then add 50µL prepared Detection Reagent A immediately.
Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
7. Read RLU value immediately.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Comparative Biochemistry and Physiology Part C: Toxicology & Pharmacology | Effects of ectoine on behavioural, physiological and biochemical parameters of Daphnia magna Pubmed:25460046 |
PLoS One. | Comparative Proteomics Identifies Host Immune System Proteins Affected by Infection with Mycobacterium bovis Pubmed:27027307 |
Parasites & Vectors | The intracellular bacterium Anaplasma phagocytophilum selectively manipulates the levels of vertebrate host proteins in the tick vector Ixodes scapularis. pubmed:27561965 |
Proteomics. Clinical Applications | Elevated levels of protein AMBP in cerebrospinal fluid of women with preeclampsia compared to normotensive pregnant women. pubmed:27615121 |
Molecular nutrition & food research | Chicory inulin ameliorates type 2 diabetes mellitus and suppresses JNK and MAPK pathways in vivo and in vitro pubmed:28105758 |
Frontiers in Immunology | Oxidized Hemoglobin Is Antigenic and Immunogenic in Lupus pubmed:28694810 |
新規人工酸素運搬体HemoAct を用いた脳虚血再灌流障害治療開発に関する研究 : | |
Acta Neuropathologica Communications | Mural cell-derived laminin-α5 plays a detrimental role in ischemic stroke Pubmed: 30777135 |
Angiogenesis | Decylubiquinone suppresses breast cancer growth and metastasis by inhibiting angiogenesis via the ROS/p53/BAI1 signaling pathway Pubmed: 32020421 |
Food Bioscience | Water-extractable zinc protoporphyrin IX in Parma ham predominantly exists as complexes with hemoglobin and myoglobin |
Photochem Photobiol | Effects of Human Serum Albumin on the Fluorescence Intensity and Tumor Imaging Properties of IR‐780 Dye 34687567 |
Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
NPB409Hu01 | Native Hemoglobin (HB) | Positive Control; Immunogen; SDS-PAGE; WB. |
NPB409Hu02 | Native Hemoglobin (HB) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAB409Hu01 | Polyclonal Antibody to Hemoglobin (HB) | WB; IHC; ICC; IP. |
PAB409Hu02 | Polyclonal Antibody to Hemoglobin (HB) | WB; IHC; ICC; IP. |
LAB409Hu81 | FITC-Linked Polyclonal Antibody to Hemoglobin (HB) | WB; IHC; ICC; IF. |
LAB409Hu71 | Biotin-Linked Polyclonal Antibody to Hemoglobin (HB) | WB; IHC; ICC. |
CEB409Hu | ELISA Kit for Hemoglobin (HB) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CCB409Hu | CLIA Kit for Hemoglobin (HB) | Chemiluminescent immunoassay for Antigen Detection. |
LMB409Hu | Multiplex Assay Kit for Hemoglobin (HB) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
KSB409Hu11 | ELISA Kit DIY Materials for Hemoglobin (HB) | Main materials for "Do It (ELISA Kit) Yourself". |