Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
High Sensitive ELISA Kit for Oxytocin Receptor (OXTR)
OT-R
- Product No.HEC705Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample TypeTissue homogenates, cell lysates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3h
- Detection Range78-5,000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 30pg/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 539
For more details, please contact local distributors! US$ 770 US$ 3465 US$ 6545 US$ 53900
Specificity
This assay has high sensitivity and excellent specificity for detection of High Sensitive Oxytocin Receptor (OXTR).
No significant cross-reactivity or interference between High Sensitive Oxytocin Receptor (OXTR) and analogues was observed.
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level High Sensitive Oxytocin Receptor (OXTR) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level High Sensitive Oxytocin Receptor (OXTR) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Cephalalgia | Oxytocin receptor: Expression in the trigeminal nociceptive system and potential role in the treatment of headache disorders PubMed: 26590611 |
Biol Pharm Bull | Targeting the oxytocin system to ameliorate early life depressive-like behaviors in maternally-separated rats 34349049 |
Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
RPC705Hu01 | Recombinant Oxytocin Receptor (OXTR) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAC705Hu01 | Polyclonal Antibody to Oxytocin Receptor (OXTR) | WB; IHC; ICC; IP. |
MAC705Hu22 | Monoclonal Antibody to Oxytocin Receptor (OXTR) | WB; IHC; ICC; IP. |
HEC705Hu | High Sensitive ELISA Kit for Oxytocin Receptor (OXTR) | Enzyme-linked immunosorbent assay for Antigen Detection. |
SEC705Hu | ELISA Kit for Oxytocin Receptor (OXTR) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMC705Hu | Multiplex Assay Kit for Oxytocin Receptor (OXTR) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |