ELISA Kit for Oxytocin Receptor (OXTR)

OT-R

Specificity

This assay has high sensitivity and excellent specificity for detection of Oxytocin Receptor (OXTR).
No significant cross-reactivity or interference between Oxytocin Receptor (OXTR) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Oxytocin Receptor (OXTR) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Oxytocin Receptor (OXTR) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Cephalalgia Oxytocin receptor: Expression in the trigeminal nociceptive system and potential role in the treatment of headache disorders PubMed: 26590611
Biol Pharm Bull Targeting the oxytocin system to ameliorate early life depressive-like behaviors in maternally-separated rats 34349049
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPC705Hu01 Recombinant Oxytocin Receptor (OXTR) Positive Control; Immunogen; SDS-PAGE; WB.
PAC705Hu01 Polyclonal Antibody to Oxytocin Receptor (OXTR) WB; IHC; ICC; IP.
MAC705Hu22 Monoclonal Antibody to Oxytocin Receptor (OXTR) WB; IHC; ICC; IP.
HEC705Hu High Sensitive ELISA Kit for Oxytocin Receptor (OXTR) Enzyme-linked immunosorbent assay for Antigen Detection.
SEC705Hu ELISA Kit for Oxytocin Receptor (OXTR) Enzyme-linked immunosorbent assay for Antigen Detection.
LMC705Hu Multiplex Assay Kit for Oxytocin Receptor (OXTR) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.