Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Inhibin Beta E (INHbE) ,etc. by FLIA (Flow Luminescence Immunoassay)
INH-bE; Activin beta-E chain
(Note: Up to 8-plex in one testing reaction)
- Product No.LMA048Mu
- Organism SpeciesMus musculus (Mouse) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates and other biological fluids
- Test MethodCompetitive Inhibition
- Assay Length1.5h
- Detection Range0.24-250pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.08 pg/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 405
US$ 420
US$ 443
US$ 475
US$ 506
US$ 552
US$ 622
Result
For more details, please contact local distributors! US$ 778 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Inhibin Beta E (INHbE) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Inhibin Beta E (INHbE) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Inhibin Beta E (INHbE) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Inhibin Beta E (INHbE) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 78-92 | 85 |
EDTA plasma(n=5) | 89-103 | 98 |
heparin plasma(n=5) | 88-102 | 92 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Inhibin Beta E (INHbE) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Inhibin Beta E (INHbE) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Inhibin Beta E (INHbE) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 98-105% | 87-99% | 82-101% | 87-94% |
EDTA plasma(n=5) | 83-98% | 85-95% | 83-104% | 83-97% |
heparin plasma(n=5) | 91-98% | 92-105% | 97-105% | 98-105% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:INHbE) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Mitochondrion | GDF15 is a novel biomarker to evaluate efficacy of pyruvate therapy for mitochondrial diseases Pubmed:25446397 |
PLoS One | Inhibin βE (INHBE) is a possible insulin resistance-associated hepatokine identified by comprehensive gene expression analysis in human liver biopsy … Pubmed:29596463 |
Cell Reports | Activin E Controls Energy Homeostasis in Both Brown and White Adipose Tissues as a Hepatokine Pubmed: 30380411 |
International Journal of Pharmacy and Biological Sciences | Anti-Obesity Efficacy of Selected Plants Against Progesterone Induced Obesity |
Catalog No. | Related products for research use of Mus musculus (Mouse) Organism species | Applications (RESEARCH USE ONLY!) |
RPA048Mu01 | Recombinant Inhibin Beta E (INHbE) | Positive Control; Immunogen; SDS-PAGE; WB. |
RPA048Mu02 | Recombinant Inhibin Beta E (INHbE) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA048Mu01 | Polyclonal Antibody to Inhibin Beta E (INHbE) | WB; IHC |
PAA048Mu02 | Polyclonal Antibody to Inhibin Beta E (INHbE) | WB; IHC; ICC; IP. |
SEA048Mu | ELISA Kit for Inhibin Beta E (INHbE) | Enzyme-linked immunosorbent assay for Antigen Detection. |
HEA048Mu | High Sensitive ELISA Kit for Inhibin Beta E (INHbE) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CEA048Mu | ELISA Kit for Inhibin Beta E (INHbE) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA048Mu | Multiplex Assay Kit for Inhibin Beta E (INHbE) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |