Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Thrombomodulin (TM) ,etc. by FLIA (Flow Luminescence Immunoassay)
CD141; THBD; BDCA3; THRM; Fetomodulin
(Note: Up to 8-plex in one testing reaction)
- Product No.LMA529Mu
- Organism SpeciesMus musculus (Mouse) Same name, Different species.
- Sample Typeplasma
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range1.95-2000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.65 pg/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 348
US$ 362
US$ 382
US$ 409
US$ 436
US$ 476
US$ 536
Result
For more details, please contact local distributors! US$ 670 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Thrombomodulin (TM) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Thrombomodulin (TM) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Thrombomodulin (TM) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Thrombomodulin (TM) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 80-102 | 88 |
EDTA plasma(n=5) | 84-96 | 87 |
heparin plasma(n=5) | 79-92 | 87 |
sodium citrate plasma(n=5) | 78-91 | 87 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Thrombomodulin (TM) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Thrombomodulin (TM) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Thrombomodulin (TM) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 93-101% | 86-94% | 82-97% | 81-96% |
EDTA plasma(n=5) | 95-102% | 81-103% | 99-105% | 89-98% |
heparin plasma(n=5) | 89-98% | 86-101% | 84-92% | 83-90% |
sodium citrate plasma(n=5) | 78-98% | 81-102% | 85-101% | 96-105% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:TM) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
PLoS One | A Non-Lethal Traumatic/Hemorrhagic Insult Strongly Modulates the Compartment-Specific PAI-1 Response in the Subsequent Polymicrobial Sepsis PubMed: PMC3568129 |
Clin Appl Thromb Hemost. | Is There Any Association Between Thrombosis and Tissue Factor Pathway Inhibitor Levels in Patients With Vitamin D Deficiency? Pubmed: 24203351 |
медицинские науки | КЛЕТОЧНО-МОЛЕКУЛЯРНЫЕ МАРКЕРЫ ЭНДОТЕЛИАЛЬНОЙ ДИСФУНКЦИИ И СИСТЕМНОГО ГЕМОСТАЗА ПРИ ВИБРАЦИОННОЙ БОЛЕЗНИ В … Ru:Source |
FASEB J. | Endothelial mineralocorticoid receptor activation enhances endothelial protein C receptor and decreases vascular thrombosis in mice Pubmed:24451386 |
Gynecol Endocrinol. | The effect of hormone therapy on biochemical and ultrasound parameters associated with atherosclerosis in 46, XY DSD individuals with female phenotype Pubmed:24911331 |
Informa Healthcare | Changes in cardiac thrombomodulin and heat shock transcription factor 1 expression and peripheral thrombomodulin and catecholamines during hypothermia in rats Pubmed:25109347 |
Bone Marrow Transplant. | Thrombomodulin alleviates murine GVHD in association with an increase in the proportion of regulatory T cells in the spleen Pubmed:25243628 |
Biomed Res Int | Basic Fibroblast Growth Factor Ameliorates Endothelial Dysfunction in Radiation-Induced Bladder Injury PubMed: 26351640 |
Molecular Nutrition & Food Research | Trans‐fatty acid promotes thrombus formation in mice by aggravating antithrombogenic endothelial functions via Toll‐like receptors PubMed: 25546502 |
Acta Biomater | Antioxidant and bone repair properties of quercetin-functionalized hydroxyapatite: an in vitro osteoblast-osteoclast-endothelial cell co-culture study PubMed: 26689470 |
MEDICINE AND EDUCATION IN SIBERIA | КЛЕТОЧНО-МОЛЕКУЛЯРНЫЕ МАРКЕРЫ ЭНДОТЕЛИАЛЬНОЙ ДИСФУНКЦИИ И СИСТЕМНОГО ГЕМОСТАЗА ПРИ ВИБРАЦИОННОЙ БОЛЕЗНИ В СОЧЕТАНИИ С АРТЕРИАЛЬНОЙ ГИПЕРТЕНЗИЕЙ Cozo: Mos |
Acta Biomaterialia | Antioxidant and bone repair properties of quercetin-functionalized hydroxyapatite: An in vitro osteoblast–osteoclast–endothelial cell co-culture study Pubmed:26689470 |
Bone Marrow Transplantation | The fifth epidermal growth factor-like region of thrombomodulin exerts cytoprotective functionand prevents SOS in a murine model. pubmed:27427915 |
BMC Vet Res. | Blood markers of fibrinolysis and endothelial activation in canine babesiosis. pubmed:28363279 |
Haematologica | Cytoprotective and pro-angiogenic functions of thrombomodulin are preserved in the C loop of the fifth epidermal growth factor-like domain Pubmed:29903766 |
Biomedicine & Pharmacotherapy | Puerarin prevents vascular endothelial injury through suppression of NF-κB activation in LPS-challenged human umbilical vein endothelial cells Pubmed:29775893 |
Scientific Reports | Association between Upper-airway Surgery and Ameliorative Risk Markers of endothelial function in obstructive Sleep Apnea Pubmed: 31882827 |
Intensive Care Medicine Experimental | Preservation of renal endothelial integrity and reduction of renal edema by aprotinin does not preserve renal perfusion and function following experimental … 34169407 |
Catalog No. | Related products for research use of Mus musculus (Mouse) Organism species | Applications (RESEARCH USE ONLY!) |
RPA529Mu02 | Recombinant Thrombomodulin (TM) | Positive Control; Immunogen; SDS-PAGE; WB. |
RPA529Mu01 | Recombinant Thrombomodulin (TM) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA529Mu01 | Polyclonal Antibody to Thrombomodulin (TM) | WB; IHC; ICC; IP. |
PAA529Mu02 | Polyclonal Antibody to Thrombomodulin (TM) | WB; IHC; ICC; IP. |
LAA529Mu71 | Biotin-Linked Polyclonal Antibody to Thrombomodulin (TM) | WB; IHC; ICC. |
SEA529Mu | ELISA Kit for Thrombomodulin (TM) | Enzyme-linked immunosorbent assay for Antigen Detection. |
SCA529Mu | CLIA Kit for Thrombomodulin (TM) | Chemiluminescent immunoassay for Antigen Detection. |
LMA529Mu | Multiplex Assay Kit for Thrombomodulin (TM) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |