Multiplex Assay Kit for Granzyme A (GZMA) ,etc. by FLIA (Flow Luminescence Immunoassay)

CTLA3; HFSP; HF; H factor; Granzyme 1; Fragmentin-1; Hanukkah factor; Cytotoxic T-Lymphocyte-Associated Serine Esterase 3; CTL tryptase; Cytotoxic T-lymphocyte proteinase 1

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Granzyme A (GZMA) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Granzyme A (GZMA) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Granzyme A (GZMA) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Granzyme A (GZMA) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 93-101 96
EDTA plasma(n=5) 80-104 89
heparin plasma(n=5) 94-105 99
sodium citrate plasma(n=5) 90-102 98

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Granzyme A (GZMA) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Granzyme A (GZMA) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Granzyme A (GZMA) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 94-102% 87-99% 99-105% 85-101%
EDTA plasma(n=5) 92-99% 98-105% 98-105% 90-104%
heparin plasma(n=5) 94-105% 88-104% 95-105% 91-98%
sodium citrate plasma(n=5) 80-89% 84-96% 98-105% 96-104%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:GZMA) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Cell Reports Granzyme A Produces Bioactive IL-1β through a Nonapoptotic Inflammasome-Independent Pathway Pubmed:25437548
Journal of Dermatological Science Relationships among plasma granzyme B level, pruritus and dermatitis in patients with atopicdermatitis. pubmed:27686401
Journal of Maternal-Fetal & Neonatal Medicine Extracellular granzyme A in amniotic fluid is elevated in the presence of sterile intra-amniotic inflammation in preterm prelabor rupture of membranes Pubmed: 32912008
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
RPA599Mu01 Recombinant Granzyme A (GZMA) Positive Control; Immunogen; SDS-PAGE; WB.
RPA599Mu02 Recombinant Granzyme A (GZMA) Positive Control; Immunogen; SDS-PAGE; WB.
PAA599Mu02 Polyclonal Antibody to Granzyme A (GZMA) WB; IHC; ICC; IP.
PAA599Mu01 Polyclonal Antibody to Granzyme A (GZMA) WB
LAA599Mu71 Biotin-Linked Polyclonal Antibody to Granzyme A (GZMA) WB; IHC; ICC.
SEA599Mu ELISA Kit for Granzyme A (GZMA) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA599Mu Multiplex Assay Kit for Granzyme A (GZMA) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA599Mu01 ELISA Kit DIY Materials for Granzyme A (GZMA) Main materials for "Do It(ELISA Kit) Yourself"