Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Chemerin (CHEM) ,etc. by FLIA (Flow Luminescence Immunoassay)
TIG2; RARRES2; Tazarotene-Induced Gene 2; Retinoic Acid Receptor Responder 2,Tazarotene Induced; RAR-responsive protein TIG2
(Note: Up to 8-plex in one testing reaction)
- Product No.LMA945Ra
- Organism SpeciesRattus norvegicus (Rat) Same name, Different species.
- Sample Typeserum, plasma, tissue homogenates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range0.98-1000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.327 pg/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 427
US$ 443
US$ 468
US$ 501
US$ 534
US$ 583
US$ 657
Result
For more details, please contact local distributors! US$ 821 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Chemerin (CHEM) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Chemerin (CHEM) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Chemerin (CHEM) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Chemerin (CHEM) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 84-91 | 87 |
EDTA plasma(n=5) | 84-93 | 88 |
heparin plasma(n=5) | 86-104 | 95 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Chemerin (CHEM) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Chemerin (CHEM) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Chemerin (CHEM) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 81-89% | 99-105% | 78-103% | 92-104% |
EDTA plasma(n=5) | 96-103% | 97-105% | 79-90% | 79-104% |
heparin plasma(n=5) | 80-88% | 93-101% | 86-97% | 78-94% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:CHEM) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Scandinavian Journal of Gastroenterology | Serum chemerin and vaspin in non-alcoholic fatty liver disease PubMed: 20095887 |
Gastroenterology & Hepatology | Chemerin, vaspin and insulin resistance in chronic hepatitis C Wiley: source |
Placenta | Expression and regulation of chemerin during rat pregnancy ScienceDirect: S0143400412000902 |
Acta Pharmacologica Sinica | Chronic ethanol consumption increases the levels of chemerin in the serum and adipose tissue of humans and rats Nature: 201211 |
RAED dergisi | Ankilozan spondilitli hastalarda adipositokin düzeyleri ve insülin direnci Raeddergisi: Source |
Journal of Cellular and Molecular Medicine | Association of chemerin with oxidative stress, inflammation and classical adipokines in non-diabetic obese patients Pubmed: 24702860 |
Clinical Endocrinology | Strong correlations between circulating chemerin levels and lipoprotein subfractions in nondiabetic obese and nonobese subjects Pubmed: 24303851 |
Oral Dis. | Impact of OSA on Biological Markers in Morbid Obesity and Metabolic Syndrome Pubmed:24106991 |
Endocrine | Chemerin plays a protective role by regulating human umbilical vein endothelial cell-induced nitric oxide signaling in preeclampsia Pubmed:24840719 |
The Clinical Respiratory Journal | Relationship between plasma chemerin levels and disease severity in COPD patients Pubmed:24865134 |
Gynecol Endocrinol. | Elevated serum chemerin in Chinese women with hyperandrogenic PCOS Pubmed:24927079 |
Endocrine. | Protective effect of liraglutide against ER stress in the liver of high-fat diet-induced insulin-resistant rats. Pubmed:25471281 |
Obesity Surgery | Long-term Effect of Ileal Transposition on Adipokine Serum Level in Zucker (Orl)-Lepr fa Fatty Rats Pubmed:25697126 |
Dermatologica Sinica | Chemerin and calprotectin levels correlate with disease activity and inflammation markers in psoriasis vulgaris Sciencedirect:S1027811714000470 |
Dis Markers | Serum Chemerin Levels in relation to Osteoporosis and Bone Mineral Density: A Case-Control Study PubMed: 26170530 |
Med Sci Monit | Association of Serum Chemerin Levels with Acute Ischemic Stroke and Carotid Artery Atherosclerosis in a Chinese Population PubMed: 26471865 |
Endocrine | Protective effect of liraglutide against ER stress in the liver of high-fat diet-induced insulin-resistant rats PubMed: 25471281 |
Biochimica et Biophysica Acta (BBA) - Molecular and Cell Biology of Lipids | Effects of alpha-lipoic acid on chemerin secretion in 3T3-L1 and human adipocytes Pubmed:26721419 |
Medicine (Baltimore). | Association of chemerin levels and bone mineral density in Chinese obese postmenopausalwomen. pubmed:27583869 |
Oxidative Medicine and Cellular Longevity | Changes of Plasma FABP4, CRP, Leptin, and Chemerin Levels in relation to Different Dietary Patterns and Duodenal-Jejunal Omega Switch Surgery in Sprague … Pubmed:29849871 |
Current Eye Research | Chemerin is associated with diabetic retinopathy in type 2 diabetes Pubmed:25848840 |
Journal of Oral Rehabilitation | Expression of chemerin in the synovial fluid of patients with temporomandibular joint disorders Pubmed:29331039 |
International Journal of Cancer | Epigenetic regulation of Amphiregulin and Epiregulin in colorectal cancer Pubmed: 30252132 |
Experimental Gerontology | The decline of whole-body glucose metabolism in ovariectomized rats Pubmed: 30292771 |
Pancreatology | Chemerin alleviates acute pancreatitis in the rat thorough modulation of NF-κB signal Doi: 10.1016/j.pan.2019.02.005 |
Hypertens Pregnancy | Protective effect of vitamin D supplementation in a rat modal of preeclampsia: a possible implication of chemerin Pubmed: 30922121 |
Pancreatology | Chemerin alleviates acute pancreatitis in the rat thorough modulation of NF-kB signal Pubmed: 30833212 |
Digestion | Association between High Levels of Circulating Chemerin and Colorectal Adenoma in Men Pubmed: 31269491 |
Vitamin D Supplementation Reduces Serum Chemerin Level in Gestational Diabetes Mellitus Rat Model | |
Aging Medicine | Plasma levels of adiponectin and chemerin are associated with early stage of atherosclerosis in older adults with type 2 diabetes mellitus |
Eur J Nutr | The dietary inflammatory index is associated with anti-and pro-inflammatory adipokines in Brazilian schoolchildren 33575861 |
Eur J Pediatr | Pro-and anti-inflammatory adipokines are associated with cardiometabolic risk markers in Brazilian schoolchildren 33834274 |
Indian Journal of Forensic Medicine & Toxicology | Altered Serum Marker of Adipokines Profile in Breast Cancer Women |
Int J Womens Health | Association of High Serum Chemerin with Bone Mineral Density Loss and Osteoporotic Fracture in Elderly Chinese Women Pubmed:35140527 |
Catalog No. | Related products for research use of Rattus norvegicus (Rat) Organism species | Applications (RESEARCH USE ONLY!) |
RPA945Ra01 | Recombinant Chemerin (CHEM) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA945Ra01 | Polyclonal Antibody to Chemerin (CHEM) | WB; IHC; ICC; IP. |
LAA945Ra91 | HRP-Linked Polyclonal Antibody to Chemerin (CHEM) | WB; IHC; ICC. |
MAA945Ra24 | Monoclonal Antibody to Chemerin (CHEM) | WB; IHC; ICC; IP. |
MAA945Ra23 | Monoclonal Antibody to Chemerin (CHEM) | WB; IHC; ICC; IP. |
MAA945Ra22 | Monoclonal Antibody to Chemerin (CHEM) | WB |
MAA945Ra25 | Monoclonal Antibody to Chemerin (CHEM) | WB; IHC; ICC; IP. |
MAA945Ra21 | Monoclonal Antibody to Chemerin (CHEM) | WB; IHC; ICC; IP. |
SEA945Ra | ELISA Kit for Chemerin (CHEM) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA945Ra | Multiplex Assay Kit for Chemerin (CHEM) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |