Multiplex Assay Kit for Cartilage Oligomeric Matrix Protein (COMP) ,etc. by FLIA (Flow Luminescence Immunoassay)
MED; EDM1; EPD1; PSACH; THBS5; TSP-5; Pseudoachondroplasia,Epiphyseal Dysplasia 1,Multiple; Thrombospondin 5
(Note: Up to 8-plex in one testing reaction)
- Product No.LMB197Mu
- Organism SpeciesMus musculus (Mouse) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range0.01-10ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.003 ng/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 359
US$ 373
US$ 394
US$ 422
US$ 449
US$ 491
US$ 553
Result
For more details, please contact local distributors! US$ 691 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Cartilage Oligomeric Matrix Protein (COMP) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Cartilage Oligomeric Matrix Protein (COMP) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Cartilage Oligomeric Matrix Protein (COMP) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Cartilage Oligomeric Matrix Protein (COMP) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 97-105 | 101 |
EDTA plasma(n=5) | 93-101 | 96 |
heparin plasma(n=5) | 92-103 | 99 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Cartilage Oligomeric Matrix Protein (COMP) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Cartilage Oligomeric Matrix Protein (COMP) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Cartilage Oligomeric Matrix Protein (COMP) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 94-103% | 84-104% | 80-96% | 82-93% |
EDTA plasma(n=5) | 79-94% | 98-105% | 90-104% | 87-98% |
heparin plasma(n=5) | 80-99% | 90-105% | 96-103% | 85-95% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:COMP) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Chinese Medical Journal | Genetic analysis and serum level of cartilage oligomeric matrix protein in patients with pseudoachondroplasia CMJ: 201082337960590 |
BioMed Research International | Decreased Plasma COMP and Increased Plasma CTX-II Levels in a Chinese Pseudoachondroplasia Family with Novel COMP Mutation pubmed:29104872 |
Molecular Medicine Reports | Mori Folium water extract alleviates articular cartilage damages and inflammatory responses in monosodium iodoacetate‑induced osteoarthritis rats pubmed:29067461 |
Archives of Rheumatology | Cartilage Oligomeric Matrix Protein Levels in Synovial Fluid in Patients With Primary Knee Osteoarthritis And Healthy Controls: A Preliminary Comparative Analysis With Serum Cartilage Oligomeric Matrix Protein doi: 10.5606/ArchRheumatol.2017.6220 |
Genetic Testing and Molecular Biomarkers | Cartilage Oligomeric Matrix Protein Levels in Type 2 Diabetes Associated with Primary Knee Osteoarthritis Patients Pubmed: 30526057 |
International Journal of Clinical and Experimental Medicine | The relationship between the serum and synovial fluid osteopontin (OPN), cartilage oligomeric matrix protein (COMP), and the severity of knee osteoarthritis … |
British Journal of Medicine and Medical Research | Diagnostic Accuracy of Cartilage Oligomeric Matrix Protein (COMP), for Cartilage Damage in Rheumatoid Arthritis |