Multiplex Assay Kit for Cholesterol (CH) ,etc. by FLIA (Flow Luminescence Immunoassay)
(Note: Up to 8-plex in one testing reaction)
- Product No.LMB701Ge
- Organism SpeciesPan-species (General) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodCompetitive Inhibition
- Assay Length1.5h
- Detection Range0.49-500ug/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.163 ug/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 543
US$ 564
US$ 595
US$ 637
US$ 679
US$ 741
US$ 835
Result
For more details, please contact local distributors! US$ 1044 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Cholesterol (CH) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Cholesterol (CH) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of Cholesterol (CH) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Cholesterol (CH) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 93-105 | 97 |
EDTA plasma(n=5) | 78-92 | 86 |
heparin plasma(n=5) | 86-94 | 90 |
sodium citrate plasma(n=5) | 94-101 | 98 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Cholesterol (CH) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Cholesterol (CH) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Cholesterol (CH) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 85-94% | 88-99% | 81-99% | 85-93% |
EDTA plasma(n=5) | 86-98% | 98-105% | 78-98% | 86-97% |
heparin plasma(n=5) | 91-101% | 91-105% | 89-103% | 93-101% |
sodium citrate plasma(n=5) | 79-92% | 87-95% | 92-101% | 94-101% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:CH) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Journal of Cell Science | Nuclear phosphatidylinositol 4, 5-bisphosphate islets contribute to efficient RNA polymerase II-dependent transcription Pubmed:29507116 |
Journal of Diabetes Research | Regulation and Mechanism of miR-518d through the PPARα-Mediated NF-κB Pathway in the Development of Gestational Diabetes Mellitus Pubmed: 33123597 |
Vascul Pharmacol | Immune responses against oxidized LDL as possible targets for prevention of atherosclerosis in systemic lupus erythematosus 33857652 |
Evid Based Complement Alternat Med | Effect of Acupoint Embedding on Serum Leptin and Hypothalamus Leptin Receptor Expression in Rats with Simple Obesity 34659432 |
Nat Commun | GP73 is a TBC-domain Rab GTPase-activating protein contributing to the pathogenesis of non-alcoholic fatty liver disease without obesity 34853313 |
Antioxidants | Antioxidant Effect of Tyr-Ala Extracted from Zein on INS-1 Cells and Type 2 Diabetes High-Fat-Diet-Induced Mice Pubmed:35740008 |
Catalog No. | Related products for research use of Pan-species (General) Organism species | Applications (RESEARCH USE ONLY!) |
CPB701Ge11 | BSA Conjugated Cholesterol (CH) | Immunogen; SDS-PAGE; WB. |
CPB701Ge21 | OVA Conjugated Cholesterol (CH) | Immunogen; SDS-PAGE; WB. |
PAB701Ge01 | Polyclonal Antibody to Cholesterol (CH) | ELISA, CLIA. / IHC-Fr, ICC, IP (predicted). |
LAB701Ge71 | Biotin-Linked Polyclonal Antibody to Cholesterol (CH) | IHC; ICC; IP. |
CEB701Ge | ELISA Kit for Cholesterol (CH) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMB701Ge | Multiplex Assay Kit for Cholesterol (CH) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
KSB701Ge11 | ELISA Kit DIY Materials for Cholesterol (CH) | Main materials for "Do It (ELISA Kit) Yourself". |