Multiplex Assay Kit for Nucleolin (NCL) ,etc. by FLIA (Flow Luminescence Immunoassay)

C23; Protein C23

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Nucleolin (NCL) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Nucleolin (NCL) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Nucleolin (NCL) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Nucleolin (NCL) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 86-95 90
EDTA plasma(n=5) 97-104 101
heparin plasma(n=5) 98-105 102
sodium citrate plasma(n=5) 87-98 94

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Nucleolin (NCL) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Nucleolin (NCL) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Nucleolin (NCL) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 96-104% 96-103% 89-97% 78-93%
EDTA plasma(n=5) 98-105% 98-105% 88-98% 85-102%
heparin plasma(n=5) 96-104% 79-96% 95-102% 86-101%
sodium citrate plasma(n=5) 95-103% 84-91% 92-101% 89-103%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:NCL) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
European Journal of Pharmaceutics and Biopharmaceutics RNA G-quadruplex as supramolecular carrier for cancer-selective delivery
Mol Pharm Drug Loading and Functional Efficacy of Cow, Buffalo, and Goat Milk-Derived Exosomes: A Comparative Study Pubmed:35195427
Frontiers in Physiology Fine Tuning Inclusion in 2 of′-O-Methyl Phosphorothioate Oligonucleotides Contributes to Specific Cell Targeting for Splice-Switching Modulation Pubmed:34721051
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPC242Hu01 Recombinant Nucleolin (NCL) Positive Control; Immunogen; SDS-PAGE; WB.
RPC242Hu02 Recombinant Nucleolin (NCL) Positive Control; Immunogen; SDS-PAGE; WB.
RPC242Hu03 Recombinant Nucleolin (NCL) Positive Control; Immunogen; SDS-PAGE; WB.
PAC242Hu02 Polyclonal Antibody to Nucleolin (NCL) WB; IHC; ICC; IP.
PAC242Hu03 Polyclonal Antibody to Nucleolin (NCL) WB; IHC; ICC; IP.
PAC242Hu01 Polyclonal Antibody to Nucleolin (NCL) WB; IHC; ICC; IP.
MAC242Hu22 Monoclonal Antibody to Nucleolin (NCL) WB; IHC; ICC; IP.
SEC242Hu ELISA Kit for Nucleolin (NCL) Enzyme-linked immunosorbent assay for Antigen Detection.
LMC242Hu Multiplex Assay Kit for Nucleolin (NCL) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.