Multiplex Assay Kit for Ribonuclease A7 (RNASE7) ,etc. by FLIA (Flow Luminescence Immunoassay)

SAP-2; Rnase-A7; Ribonuclease,RNase A Family 7; Skin-derived antimicrobial protein 2

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Ribonuclease A7 (RNASE7) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Ribonuclease A7 (RNASE7) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Ribonuclease A7 (RNASE7) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Ribonuclease A7 (RNASE7) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 82-104 86
EDTA plasma(n=5) 90-97 94
heparin plasma(n=5) 80-96 83
sodium citrate plasma(n=5) 92-105 101

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Ribonuclease A7 (RNASE7) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Ribonuclease A7 (RNASE7) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Ribonuclease A7 (RNASE7) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 86-95% 98-105% 97-105% 96-105%
EDTA plasma(n=5) 85-102% 95-105% 94-102% 83-101%
heparin plasma(n=5) 97-105% 78-102% 80-96% 81-95%
sodium citrate plasma(n=5) 98-105% 78-91% 85-98% 97-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:RNASE7) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
International Journal of Molecular Sciences The Human Host Defense Ribonucleases 1, 3 and 7 Are Elevated in Patients with Sepsis after Major Surgery—A Pilot Study Pubmed:26927088
Scientific Reports Measurements of AMPs in stratum corneum of atopic dermatitis and healthy skin–tape stripping technique Pubmed:29374283
Scientific Reports Analysis of the Ribonuclease A superfamily of Antimicrobial peptides in patients Undergoing Chronic peritoneal Dialysis Pubmed: 31123272
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPD193Hu01 Recombinant Ribonuclease A7 (RNASE7) Positive Control; Immunogen; SDS-PAGE; WB.
PAD193Hu01 Polyclonal Antibody to Ribonuclease A7 (RNASE7) WB
LAD193Hu71 Biotin-Linked Polyclonal Antibody to Ribonuclease A7 (RNASE7) WB; IHC; ICC.
MAD193Hu21 Monoclonal Antibody to Ribonuclease A7 (RNASE7) WB; IHC; ICC; IP.
HED193Hu High Sensitive ELISA Kit for Ribonuclease A7 (RNASE7) Enzyme-linked immunosorbent assay for Antigen Detection.
SED193Hu ELISA Kit for Ribonuclease A7 (RNASE7) Enzyme-linked immunosorbent assay for Antigen Detection.
LMD193Hu Multiplex Assay Kit for Ribonuclease A7 (RNASE7) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.