Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Gastrokine 2 (GKN2) ,etc. by FLIA (Flow Luminescence Immunoassay)
TFIZ1; BLOT; GDDR; VLTI465; Blottin; Down Regulated In Gastric Cancer; Trefoil factor interactions(z) 1
(Note: Up to 8-plex in one testing reaction)
- Product No.LMJ048Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample TypeTissue homogenates and other biological fluids.
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range0.98-1000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.327 pg/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 437
US$ 454
US$ 479
US$ 512
US$ 546
US$ 596
US$ 672
Result
For more details, please contact local distributors! US$ 840 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Gastrokine 2 (GKN2) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Gastrokine 2 (GKN2) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Gastrokine 2 (GKN2) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Gastrokine 2 (GKN2) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 93-103 | 101 |
EDTA plasma(n=5) | 78-88 | 84 |
heparin plasma(n=5) | 92-101 | 96 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Gastrokine 2 (GKN2) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Gastrokine 2 (GKN2) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Gastrokine 2 (GKN2) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 78-101% | 84-102% | 86-94% | 78-99% |
EDTA plasma(n=5) | 80-101% | 79-90% | 85-93% | 85-95% |
heparin plasma(n=5) | 86-95% | 93-104% | 97-104% | 78-105% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:GKN2) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Digestive Diseases and Sciences | Gastrointestinal Factor GDDR Attenuates Epithelial–Mesenchymal Transition in Gastric Cancer via Inhibiting AKT Signal Pubmed:27017226 |
Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
RPJ048Hu01 | Recombinant Gastrokine 2 (GKN2) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAJ048Hu01 | Polyclonal Antibody to Gastrokine 2 (GKN2) | WB; IHC |
FAJ048Hu01 | Anti-Gastrokine 2 (GKN2) Polyclonal Antibody | Flow cytometry. |
LAJ048Hu71 | Biotin-Linked Polyclonal Antibody to Gastrokine 2 (GKN2) | WB; IHC; ICC. |
MAJ048Hu21 | Monoclonal Antibody to Gastrokine 2 (GKN2) | WB; IHC; ICC; IP. |
SEJ048Hu | ELISA Kit for Gastrokine 2 (GKN2) | Enzyme-linked immunosorbent assay for Antigen Detection. |
SCJ048Hu | CLIA Kit for Gastrokine 2 (GKN2) | Chemiluminescent immunoassay for Antigen Detection. |
LMJ048Hu | Multiplex Assay Kit for Gastrokine 2 (GKN2) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |