Multiplex Assay Kit for Semaphorin 3A (SEMA3A) ,etc. by FLIA (Flow Luminescence Immunoassay)
SEMAL; Hsema-I; Hsema-III; SEMA1; SEMAD; SEMAIII; SemD; Coll-1; Sema Domain,Immunoglobulin Domain(Ig),Transmembrane Domain(TM)and Short Cytoplasmic Domain 3A
(Note: Up to 8-plex in one testing reaction)
- Product No.LML917Ra
- Organism SpeciesRattus norvegicus (Rat) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range0.98-1000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.327 pg/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 522
US$ 542
US$ 572
US$ 612
US$ 652
US$ 712
US$ 802
Result
For more details, please contact local distributors! US$ 1003 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Semaphorin 3A (SEMA3A) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Semaphorin 3A (SEMA3A) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Semaphorin 3A (SEMA3A) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Semaphorin 3A (SEMA3A) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 88-97 | 92 |
EDTA plasma(n=5) | 92-99 | 95 |
heparin plasma(n=5) | 80-94 | 89 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Semaphorin 3A (SEMA3A) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Semaphorin 3A (SEMA3A) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Semaphorin 3A (SEMA3A) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 92-101% | 79-89% | 93-105% | 94-102% |
EDTA plasma(n=5) | 85-97% | 85-101% | 78-95% | 85-99% |
heparin plasma(n=5) | 98-105% | 84-91% | 93-101% | 79-95% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:SEMA3A) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Arthritis Research & Therapy | Semaphorin 3A is a marker for disease activity and a potential immunoregulator in systemic lupus erythematosus Biomed: ar3881 |
journal of invastigative dermatology | Cathelicidin LL-37 Induces Semaphorin 3A Expression in Human Epidermal Keratinocytes: Implications for Possible Application to Pruritus PubMed: 26121211 |
Neurology | Neurofilament light chain level is a weak risk factor for the development of MS. pubmed:27521440 |
Development | miR-126-5p promotes retinal endothelial cell survival through SetD5 regulatio in neurons pubmed:29180574 |
A Preliminary Study of the Effect of Semaphorin 3A and Acitretin on the Proliferation, Migration, and Apoptosis of HaCaT Cells | |
Life Sciences | Curcumin and LOXblock-1 ameliorate ischemia-reperfusion induced inflammation and acute kidney injury by suppressing the semaphorin-plexin pathway. Pubmed: 32603817 |
ACS NANO | Gold Nanoparticles Induce Tumor Vessel Normalization and Impair Metastasis by Inhibiting Endothelial Smad2/3 Signaling Pubmed: 32413258 |
PLoS One | Extract of Scutellaria baicalensis induces semaphorin 3A production in human epidermal keratinocytes 33905439 |
Catalog No. | Related products for research use of Rattus norvegicus (Rat) Organism species | Applications (RESEARCH USE ONLY!) |
APL917Ra01 | Active Semaphorin 3A (SEMA3A) | Cell culture; Activity Assays. |
RPL917Ra01 | Recombinant Semaphorin 3A (SEMA3A) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAL917Ra01 | Polyclonal Antibody to Semaphorin 3A (SEMA3A) | WB; IHC; ICC; IP. |
MAL917Ra21 | Monoclonal Antibody to Semaphorin 3A (SEMA3A) | WB; IHC; ICC; IP. |
SEL917Ra | ELISA Kit for Semaphorin 3A (SEMA3A) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LML917Ra | Multiplex Assay Kit for Semaphorin 3A (SEMA3A) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |